GIS operating principles

GIS is totally capsuled, that is impervious to and distinguished from the external ambiance. This is a huge benefit from environment viewpoint such as ocean based oil rigs, particle or mist pollution sources. Nevertheless, because the gas isolated switchgear is totally capsuled, a needed visible disconnecting means cannot be directly accomplished.

The basics of Gas Insulated Substation (GIS) for students
The basics of Gas Insulated Substation (GIS) for students (photo credit: Swapnil Bhole via Linkedin)

The grounding and disconnect switches, needed in both air and gas insulated arrangements, will have view ports in gas isolated devices.

GIS has a reduced “footprint” than a corresponding air insulated substation, usually less than half the area. Even though a gas isolated substation will initially cost more than a similar air insulated substation, the economics may rationalize its installation where land is pricey, such as city centres.

GIS may also be rationalized when a low profile substation is required to “hide” a substation.


GIS operation

As a gas isolated switchgear element is isolated for servicing, it will be required to affirm the places of the grounding and disconnect switches. Since these switches are totally cased within the aluminum enclosure, it is essential for producers to allow for view ports.

The view ports allow, by visual verification, to check the position of the different disconnect and grounding switches. In some situations, this can be completed with using just a flashlight.

In other situations, at strange access points, a camera with a light source supplied by the producer is handy.

Gas isolated devices are typically furnished with a local control cabinet (LCC). Generally, this cabinet lets in control switches for the operation of one circuit breaker and its related grounding and disconnect switches and breaker alarms.

The protective relays related with the GIS devices may or may not put in the same place. Since SF6 gas behaves as a vital insulator, it is required to keep adequate density within the GIS devices. Hence, there will be alarm and trip contacts from sensors for each gas separation to warn staff or isolate devices when the insulation integrity is insufficient.

Gas density monitoring indicator
Gas density monitoring indicator

One of the advantages of GIS devices over its air insulated equipment is the minimal servicing that is needed of the GIS. This is mainly due to the breakup of the conductors and isolators from the outside ambience. Modern GIS devices have very low SF6 gas leakage rates.

The operation counter may help in finding out if any servicing will be needed on the mechanisms, but this is generally many years between maintenance.


Safety concerns

Staff safety holds a crucial priority status when servicing a GIS. The metallic enclosure of the high voltage spaces are grounded where direct contact is not possible, except at the external links. This safety element is underlying in the GIS arrangement.

Moving elements such as operation rods or motor drives are typically protected with protective plates or showed by colouring for greater safety. In case of an internal fault, pressure relief elements open the enclosing to free the hot gas to the surrounding internal elements.

These pressure relief elements are made to guide the gas stream away from staff to save them and ensure their safety.

So even in the very rare situation of an internal arc, the safety level kept is high. This has also been verified in specific GIS type tests.

To set up GIS inside indoor or outdoor substation safety regulations are further described in IEC 61936-1. Installation regulations are presented to integrate factory assembled and type-tested GIS equipment.

Demands of grounding, accessibility, fire protection, safety of walkways and other areas are described.

Title:The basics of Gas Insulated Substation (GIS) for students – Velimir Lackovic, Char. Eng. at Continuing Education and Development, Inc.
Format:PDF
Size:377 KB
Pages:36
Download:Right here | Video Courses | Membership | Download Updates
The basics of Gas Insulated Substation (GIS) for students
The basics of Gas Insulated Substation (GIS) for students

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

2 Comments


  1. Diptendra Goswami
    Nov 22, 2018

    Want to know the formula to find creepage distance for electrical conductor for 132 kv line.


    • PRABU
      Aug 04, 2019

      Dear Sir,

      I am an electrical engineer,having 11 years of experience in Testing and Commissioning of power projects.Presently working as a protection inspector at Qatar.

      If you know any openings for electrical engineer,Kindly contact me.

Leave a Reply to Diptendra Goswami

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

sixty nine  +    =  seventy five

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).