High voltage engineering

The principal objective of lecture notes is to cover the fundamentals of high voltage laboratory techniques, to provide an understanding of high voltage phenomena, and to present the basics of high voltage insulation design and techniques.

Lecture notes on high voltage engineering
Lecture notes on high voltage engineering

MODULE-I

Conduction and breakdown in gases: Gases as insulating media, Ionisation processes. Townsend current growth equation. Current growth in the presence of secondary processes. Townsend’s criterion for breakdown. Experimental determination of ionization coefficients.

Breakdown in electronegative gases, time lags for breakdown, streamer theory of breakdown in gases, Paschen’s law, Breakdown in non-uniform field and corona discharges, Post breakdown phenomena and applications, practical considerations in using gases for insulation purposes.

MODULE-II

Conduction and breakdown in liquid dielectrics: Pure liquids and commercial liquids, conduction and breakdown in pure liquids.

Breakdown in solid dielectrics: Introduction, Intrinsic brakdown. Electromechanical breakdown,
Thermal breakdown. Breakdown of solid dielectrics in practice.

MODULE-III

Generation of high voltage and currents: Generation of high D.C, voltages, Generation of high alternating voltages, Generation of Impulse voltages. Tripping and control of impulse generators. Generation of Impulse currents.

Measurements of high voltages and currents: Measurement of high D.C. voltages. Measurement of high D.C. and impulse voltages. Introduction.. Measurement of high D.C. A.C. and impulse currents, cathode ray oscillographs for impulse voltages and currents measurements.

MODULE-IV

Non destructive testing of materials and electrical apparatus: Introduction. Measurement of D.C. resistivity. Measurement of dielectric constant and loss factor. Partial discharge measurements.

High voltage testing of electrical apparatus: Testing of insulators and bushings. Testing of isolators and circuit breakers, cables. Testing of transformers, surge diverter Radio Interference measurements.

Title:Lecture notes on high voltage engineering  – VSS University of Technology – Burla, Sambalpur, Odisha,India
Format:PDF
Size:2.5 MB
Pages:97
Download:Right here | Video Courses | Membership | Download Updates
Lecture notes on high voltage engineering
Lecture notes on high voltage engineering

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

3 Comments


  1. ajay kumar singh
    May 11, 2019

    This types of notes are very much useful. please keep on post the the technical articles.


  2. KAISHNAIR A/L CHANGALI KUTTAN NAIR
    Sep 16, 2018

    Very useful and valuable information.

    It would be very helpful if I can get information and notes on HV protection relay calibration.


  3. ALAEJANDRO FORTIN
    Apr 12, 2018

    Test Criteria for Rotating Machine regarding tip-up test for insulation power factor.

Leave a Reply to ALAEJANDRO FORTIN

Tell us what you're thinking... we care about your opinion!

EEP Academy Video Courses

The learning platform for LV/MV/HV electrical engineers. Learn from experienced engineers and sharpen up your knowledge.