Ring main distribution system

The drawback of radial electrical power distribution system can be overcome by introducing a ring main electrical power distribution system. Here one ring network of distributors is fed by more than one feeder.

Notes on electrical power generation, transmission and distribution
Notes on electrical power generation, transmission and distribution

In this case if one feeder is under fault or maintenance, the ring distributor is still energized by other feeders connected to it. In this way the supply to the consumers is not affected even when any feeder becomes out of service.

Ring mains distribution system
Ring mains distribution system

In this way, supply to the consumers connected to the healthy zone of the ring, can easily be maintained even when one section of the ring is shutdown. The number of feeders connected to the ring main electrical power distribution system depends upon the following factors.

Factor #1 – Maximum demand of the system: If it is more, then more numbers of feeders feed the ring.

Factor #2 – Total length of the ring main distributors: If it length is more, to compensate the voltage drop in the line, more feeders to be connected to the ring system.

Factor #3 – Required voltage regulation: The number of feeders connected to the ring also depends upon the permissible allowable, voltage drop of the line.

The sub distributors and service mains are taken off may be via distribution transformer at different suitable points on the ring depending upon the location of the consumers.

Sometimes, instead of connecting service main directly to the ring, sub distributors are also used to feed a group of service mains where direct access of ring distributor is not possible.


Interconnected system

In this type of system two to more than two generating station or substation are energizing the feeder ring. In this system any area from one generating station during peak load hours can be fed from other generating station which increase the efficiency of the system.

Interconnected system
Interconnected system

Now a days electrical energy is generated, transmitted and distributed in the form of A.C. But for certain applications D.C. supply is necessary.

The D.C. Supply from the substations fed to the load through distributors.

Title:Notes on power generation, transmission and distribution – Lecturers Sri S.R. Mohanty, Sri Prasanjit Das and Smt. Snehalata Samal
Format:PDF
Size:5.20 MB
Pages:89
Download:Right here | Video Courses | Membership | Download Updates
Notes on power generation, transmission and distribution
Notes on power generation, transmission and distribution

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

One Comment


  1. Chenui Festus Mbuoni
    Jan 13, 2023

    How can I have notes in Distribution network in Cameroon

Leave a Reply to Chenui Festus Mbuoni

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

7  +  one  =  

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Courses - A hand crafted cutting-edge electrical engineering knowledge