Electricity generation and transmission concept

The purpose of the electric transmission system is the interconnection of the electric energy producing power plants or generating stations with the loads. A three-phase AC system is used for most transmission lines. The operating frequency is 60 Hz in the U.S. and 50 Hz in Europe, Australia, and part of Asia.

Electricity generation, transmission and distribution guides
Electricity generation, transmission and distribution guides

Electrical energy, being a very convenient form of energy, has become fully pervasive in the modern world. As the distribution system is the link through which an individual consumer draws electrical energy from the power system, proper design of the distribution system becomes very important for reliability and maintenance of continuity of electric supply.

Detailed description of all aspects of design, construction and operation of a distribution system involves a number of steps that include planning, layout, load forecast and design, equipment, protection schemes, power quality, distribution system management and more recently distributed energy resources (DERs) at the local level.

More details of all these aspects are given in the following guides and papers.

Browse guides and papers

Note that not all documents in this section are free to download. Navigate through sub-pages to discover all documents.

Primary-side protection of distribution substation transformers

Primary-side protective devices are widely applied at load-tap transformers where the available primary fault current exceeds the device’s primary-fault interrupting rating. Overlapping protection from statistically rare high-current primary faults is afforded by the line-terminal circuit breakers and first-zone phase- and… Read more

Apr 17, 2017

Primary-side protection of distribution substation transformers

Recommended practices for maintenance of LV/MV/HV electrical equipment

This document establishes minimum recommended practices for maintenance of electrical equipment in Bureau of Reclamation hydroelectric power and large pumping plants. Included in this document are recommended maintenance activities, maintenance intervals, and references. Equipment and situations vary greatly, and sound… Read more

Mar 22, 2017

Recommended practices for maintenance of LV/MV/HV electrical equipment

General specifications for a customer-owned 69 kV outdoor substation

The following are general requirements for relaying and SCADA equipment: Specific PSE&G requirements will be provided for relays and their associated equipment, as required for the operation of circuit breakers and/or motor-operated disconnecting switches. All proposed relay designs involving the… Read more

Mar 01, 2017

General specifications for a customer-owned 69 kV outdoor substation

A case study on SCADA implementation in 220 kV substation

200/110/11kV Shivgiri substation Bijapur is newly installed substation. Under IES project, automation of new substation is done through Substation Automation System (SAS) using IEC 61850. The functions performed by Substation Automation (SA) system are in, general, switch control, data monitoring,… Read more

Dec 13, 2016

A case study on SCADA implementation in 220 kV substation

Complete power cable installation guide

Cables installed into conduits or trays have installation parameters such as maximum pulling tensions, sidewall pressure, clearance, and jamming, which must be considered. Other installations, such as buried and aerial, have different installation parameters. Most installations involve some general considerations,… Read more

Oct 30, 2016

Complete power cable installation guide

Transmission substation work practice manual

This work practice outlines the minimum requirements for the use, care and maintenance of portable earthing and shorting equipment, in transmission substations. Conduct a risk assessment and job briefing. For more on this see work practice 2.15 (Job briefing process)… Read more

Oct 23, 2016

Transmission substation work practice manual

High voltage live work and practices manual

This manual has been produced to ensure standardisation of work practices and procedures for qualified and authorised high voltage (HV) live workers undertaking high voltage live work on the Western Power Network. They ensure that HV live workers are aware… Read more

Oct 05, 2016

High voltage live work and practices manual

13 Comments


  1. ISSA SLEEHAT
    May 13, 2022

    so brilliant …
    thanks and best regards.


  2. Hernán Perez
    Dec 10, 2021

    I would like to work with you


  3. Awudu nwuku aji
    Nov 05, 2021

    Electrical engineering student
    Interested in the portal


  4. samer habib
    May 29, 2020

    The best ever useful info source for Electrical engineers in practice and theory


  5. Onuajula Briggs Chidera
    Dec 31, 2019

    Thank you Sir for this lesson, am writing an Engineering article on “HVDC as a better alternative to HVAC”


  6. Mr. Hla Myint Moe
    Jul 26, 2019

    How to download this book?


  7. Abhinab Sharma
    Jun 10, 2018

    What is effect of use of shunt capacitor installed in 33 KV side at 132/33 KV grid station ?


  8. Abhinab Sharma
    Jun 10, 2018

    What is function of OLTC ( On load Tap changer) in 132/33 KV power transformer 132 KV side at 132/33 KV grid station? & When to use it ?


  9. Abhinab Sharma
    Jun 10, 2018

    What is reason of low voltage ( 116 KV) supply at 132 KV level at 132/33 KV grid station coming from 220/132 KV grid Station during peak load hours ?


  10. Khaled Yemen
    Dec 30, 2017

    Good books


  11. V SOMANATH
    Jul 25, 2017

    Sir,please tell how to join practical or video training on electrical engineering like about industrial automation&PLC scada course.or any other like autocad on electrical engineering subjects.
    Please confirm any information about this I want immediately this.


  12. walid mahjoub
    Aug 12, 2016

    good technical manuals


  13. Bhupendra Fumakia
    Aug 11, 2016

    Dear Sir,

    Please let me have PDF version of following

    “Transmission and Distribution Electrical Engineering – Colin Bayliss, Colin R. Bayliss, Brian J. Hardy”

    Best regards.

    Bhupendra

Leave a Comment

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.