Search

Premium Membership

Save 15% on Pro Premium Plan with discount code: SX79 (expires on May 31st). Study specialized LV/MV/HV technical articles and papers.

Power cable installation

Cables installed into conduits or trays have installation parameters such as maximum pulling tensions, sidewall pressure, clearance, and jamming, which must be considered. Other installations, such as buried and aerial, have different installation parameters.

Complete power cable installation guide
Complete power cable installation guide (photo credit: ABB)

Most installations involve some general considerations, such as field handling, storage, training of ends, and junction box sizes. These and other considerations can make the difference between a good installation and one resulting in damaged cable.

Cable damaged during installation can cause service failures. Mechanical stresses during installation are generally more severe than those encountered while in service.

The following information provides guidance in recognizing these conditions and provides a methodology to aid in keeping them within acceptable limits.

Pulling Cable in Duct
Pulling Cable in Duct

General field services

The small details can make the difference between successful installations and having to remove damaged cable. In preparing for a cable pull, it is just as important to cover the small details as it is to assure that the cable does not exceed maximum sidewall pressure; minimum bending radii and maximum pulling tensions.

General field practices are provided to aid in preparing for large and small cable installations.

Low temperatures are a cause for concern when installing cables! Cable should be han- dled more carefully and pulled more slowly during cold weather. When cables are to be installed in cold weather, they should be kept in heated storage for at least 24 hours before installation.

In climates where there are large temperature swings either intermittently or from summer to winter, jacket movement and shrink back can occur at splices and terminations. This is probably due to a ratcheting effect associated with the expansion and contraction cycles of the environment and cable.

NOTE: Under certain conditions, terminations may allow entry of moisture and contaminants into the cable, thus precipitating insulation failure.

Mechanical restraints, such as hose clamps and shrinkable sleeves that extend over part of the jacket and termination, that apply pressure at those points, have proven to be effective at restraining the jacket movement

Title:Complete power cable installation guide – Southwire Company
Format:PDF
Size:2.5 MB
Pages:49
Download:Right here | Video Courses | Membership | Download Updates
Complete power cable installation guide
Complete power cable installation guide

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

2 Comments


  1. Gabriel Ona
    Mar 24, 2022

    What a useful materials


  2. K.Ramakrishnan
    Jun 06, 2017

    Really superb articles..only thing you have to ensure Dependability ..

Leave a Reply to K.Ramakrishnan

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

  ⁄  1  =  five

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).