Search

Premium Membership

Study specialized technical articles, papers & courses in low/high voltage fields. Save 50% on all courses at the EEP Academy with the Enterprise Plan.

Home / Download Center / Electrical Engineering Books and Technical Guides / Electricity generation, t&d guides / Lecture notes on power system engineering for students (6th and 7th semester B.Tech)

Philosophy of Protection

The purpose of an Electric Power System is to generate and supply electrical energy to consumers. The power system should be designed and managed to deliver this energy to the utilization points with both reliability and economically.

Lecture notes on power system engineering
Lecture notes on power system engineering

The capital investment involved in power system for the generation, transmission and distribution is so great that the proper precautions must be taken to ensure that the equipment not only operates as nearly as possible to peak efficiency, but also must be protected from accidents.

The normal path of the electric current is from the power source through copper (or aluminium) conductors in generators, transformers and transmission lines to the load and it is confined to this path by insulation.

Nature of Faults:

  1. Short circuit fault- current
  2. Open circuit fault- voltage
In terms of seriousness of consequences of a fault, short circuits are of far greater concern than open circuits, although some open circuits present some potential hazards to personnel.

Classification of short circuited Faults:

  1. Three phase faults (with or without earth connection)
  2. Two phase faults (with or without earth connection)
  3. Single phase to earth faults

Classification of Open Circuit Faults:

  1. Single Phase open Circuit
  2. Two phase open circuit
  3. Three phase open circuit

Causes of Faults: The insulation, however, may break down, either by the effect of temperature and age or by a physical accident, so that the current then follows an abnormal path generally known as Short Circuit or Fault.

  1. Any abnormal operating state of a power system is known as FAULT.
  2. A fault in general consists of short circuits as well as open circuits.
  3. Open circuit faults are less frequent than short circuit faults, and often they are transformed in to short circuits by subsequent event.

Consequences of occurrence of faults:

  1. Expensive damage to the equipment due to abnormally large currents, unbalanced currents, or low voltages produced by the short circuits.
  2. Explosions which may occur in equipment containing insulating oil during short circuits and which may cause fire resulting in serious hazard to personnel and to other equipment.
  3. Sever drop in voltage which is likely to cause the individual generators in a power station or a group of generators in different stations to loose synchronism and fall out of step with consequent splitting of the system.
  4. A risk of synchronous motors in large industrial premises falling out of step and tripping out.
Title:Lecture notes on power system engineering – A course in 7th semester of Bachelor of technology programme in electrical engineering by Department of electrical engineering Veer Surendra Sai University of technology, Burla
Format:PDF
Size:5.40 MB
Pages:206
Download:Right here | Video Courses | Membership | Download Updates
Lecture notes on power system engineering (6th and 7th Semester B.Tech)
Lecture notes on power system engineering (6th and 7th Semester B.Tech)

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

3 Comments


  1. Caroly Kwawe
    Jun 11, 2021

    Good work


  2. OKONKWO CHINAGOLUM
    Jul 04, 2020

    I optimistic that one day my quest to be among the best Engineers in the World will materialise, despite the lack of opportunity to practice and to learn more.
    I am thinking that my helper will surely locate me some day


  3. David Wanyonyi Sirengo
    Jul 04, 2020

    very educative site

Leave a Reply to David Wanyonyi Sirengo

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

forty eight  ⁄  six  =  

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).