Search

Premium Membership ♕

Save 50% on all EEP Academy courses with Enterprise Membership Plan and study specialized LV/MV/HV technical articles & guides.

Home / Download Center / Electrical Engineering Books and Technical Guides / Power substation guides / Case study of distribution substation adapting IEC 61850 protection system

Reasons to make substation digital

Existing substation technology has a lot of issues in terms of designing and installing field wiring, and the number of protective relays required for protection. The constraint on using technology is more the perception of the functionality or practicality.

Case study of distribution substation adapting IEC 61850 protection system
Case study of distribution substation adapting IEC 61850 protection system

Field wiring, and field wiring design and installation, is directly addressed by the IEC 61850 standard for digital communications in a substation. However, the perception of what the standard is, or should be, limits the practical applications and design choices.

The term “IEC 61850” is associated with many concepts, and has negative connotations that include “complicated”, “complete change in design philosophy”, and “communications network based”.

This results in the perception that IEC 61850 technology is not ready for widespread adoption, or is too complex to be of value for simple projects such as a protection for a small rural substation.

A particular perception is that IEC 61850 requires a significant learning curve in software and communications skills to deliver protection and control solutions.

Multiple zone protective relays that provide up to 6 zones of independent protection exist today, and are commercially available. However, their use is limited, as the perception is that field wiring is a significant issue.

Assuming each feeder requires 4 currents, 3 status points, and 2 control points results in each feeder requiring 9 pairs of copper wires. This requires 54 pairs of copper wires for such a relay, a difficult and impractical design. Other perceptions include that operating and maintaining such a relay is more complex procedurally, as isolation for test is more difficult.

Initial protection system design
Initial protection system design

IEC 61850 technical concepts

To address this negative perception of IEC 61850, and multi-zone protective relays, it is useful to look at the three powerful technical concepts contained within the IEC 61850 standard. These concepts are self-description of data, peer-to-peer communications of data, and the publishing of sampled value data.

In IEC 61850, self-description of data is accomplished through the object-oriented modeling of logical nodes.

Peer-to-peer communications include GOOSE messaging to replace field wiring between devices, and client-server communications through the MMS protocol.

Sampled value data is the use of “merging units” to sample currents and voltages, and to publish these samples in a digital format so that microprocessor devices can use these samples for magnitude and angle measurement for protection and metering purposes.

Title:Case study of distribution substation adapting IEC 61850 protection system – Rich Hunt (GE Digital Energy), John Coursey, Stephen Hirsch (Orion New Zealand Limited)
Format:PDF
Size:1.80 MB
Pages:14
Download:Right here | Video Courses | Membership | Download Updates
Case study of a distribution substation adopting IEC 61850 protection system
Case study of a distribution substation adopting IEC 61850 protection system

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

2 Comments


  1. Bolokoto Lobito Abel
    Jul 27, 2020

    This is wonderful


  2. t.nazir
    Jun 14, 2019

    برق در زمان خطرات زیاد دارد باید هروقت از وسایل ایمنی استفاده گردد

Leave a Reply to Bolokoto Lobito Abel

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

  +  fifty five  =  65

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Hand-Crafted Courses
MV Switchgear Components