Home / Download Center / Electrical Engineering Books and Technical Guides / Power substation guides / Substation Automation Systems Based On IEC 61850 Communications Standard

IEC 61850 Communications

Metropolitan Electricity Authority’s electric power system network serves Bangkok and the neighboring areas of Nonthaburi and Samut Prakarn. The network includes more than 148 substations and terminal stations.

Substation Automation Systems Based On IEC 61850 Communications Standard
Substation Automation Systems Based On IEC 61850 Communications Standard (photo credit: Edvard Csanyi, EEP)

Metropolitan Electricity Authority (MEA) has determined that the IEC 61850 communications standard and an Ethernet Substation LAN shall be used as the cornerstones of the technological infrastructure.

What is fundamentally required is a migration plan that allows MEA to begin reaping the benefits of an IEC 61850-based architecture, while recognizing that the realities of priorities and resource constraints will stretch the full conversion of these stations over a period of years.

The full extent of this plan is illustrated by the block diagram in Figures 1.

Figure 1 shows the scope of Substation Automation (SA) configuration governed by this specification. Bay Control Units, Protection Relays and IEDs are included, the core architecture for an IEC 61850-based system is introduced.

Substation automation IEC 61850 fully implemented
Figure 1 – Substation automation IEC 61850 fully implemented

Figure 1 illustrates the eventual goal: a flexible, capable secondary system environment that is fully networked and responsive to evolving business needs.


Station Communications

Substation LAN

Two redundant Substation LANs shall provide the principal means for data exchange among intelligent station components at both the station and bay levels. Each LAN shall consist of Ethernet network segments, Ethernet switches, and TCP/IP communications software that conform to the IEC 61850 network profile.

Fiber-optic network media shall be used throughout the station facility. Copper media may be used within station level enclosures (CCU, CGW, MMI and DTS).

Each device connected to the network shall be specified to have one or two network ports, used as follows:

  • Where two ports are used, one shall be connected to each Substation LAN. The way these two connections are used is described under the ‘Dual Substation LAN Connections’ heading.
  • Where one port is used, it will be connected to an assigned Substation LAN, as determined by system design.

Gateway for Enterprise Communications

MEA has two SCADA/EMS systems that are presently the only enterprise clients that gather data from stations and provide control over their operation.

Their primary objective is to provide operational reliability for the power system.

They achieve this by monitoring power system data, status for various devices, events, counters that register energy transfer, and by controlling devices such as circuit breakers, disconnecting switches, and transformer OLTCs. Only one SCADA/EMS system has control and data acquisition responsibilities for any given station at any given time.

Title:Substation Automation Systems Based On IEC 61850 Communications Standard – Power System Maintenance Department
Format:PDF
Size:845 KB
Pages:120
Download:Right here | Video Courses | Membership | Download Updates
Substation Automation Systems Based On IEC 61850 Communications Standard
Substation Automation Systems Based On IEC 61850 Communications Standard

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

One Comment


  1. Muhammad Akram
    Feb 14, 2021

    I am going to commission 08 No.200KVA Transfopower Transformers at the BRTS Green Line Project at Karachi Pakistan. Your Technical information are useful for my self as Additional Project Manager (Electrical)

    Best Regards.
    Muhammad Akram

Leave a Reply to Muhammad Akram

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

twelve  ⁄  four  =  

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).