Search

Premium Membership

Save 15% on Pro Premium Plan with discount code: SX79 (expires on May 31st). Study specialized LV/MV/HV technical articles and papers.

Home / Download Center / Electrical Engineering Books and Technical Guides / Power substation guides / IEC 61850 standard application examples of substation automation

Why IEC 61850?

The IEC 61850 standard has been defined in cooperation with manufacturers and users to create a uniform, future-proof basis for the protection, communication and control of substations. In this brochure, we present some application examples and implemented stations with the new IEC 61850 communication standard.

IEC 61850 standard application examples of substation automation
IEC 61850 standard application examples of substation automation

IEC 61850 already has an excellent track record as the established communication standard on the worldwide market for the automation of substations.


Switchgear Interlocking with IEC 61850-G00SE

Fast communication directly between protection devices and bay control units according to IEC 61850 – GOOSE can be used to implement switchgear interlocking across bays (substation interlocking).

GOOSE stands for “generic object-oriented substation event” and is an especially fast communication service that functions independently of communication between the server (bay control unit) and client (centralized station controller).

And, as the system configurator software provides a view across devices, simple engineering of the substation interlocking is possible independent from the station level.


Task

In the simple example described here, the coupler and the two feeders of a double busbar system exchange the information items necessary for substation interlocking (Fig. 1).

Double busbar system with 2 feeders
Figure 1 – Double busbar system with 2 feeders

The information to be exchanged for substation interlocking are the following:

1. From the coupler to the feeders:

Information that the coupler is closed. If this condition is met, the disconnectors may always be operated in the feeder bays (even if the circuit-breakers of the feeders are closed).


2. From the feeders to the coupler:

Information that the busbars are connected via the disconnectors. As soon as the two busbar disconnectors are closed in at least one bay, coupler C02 can no longer be opened because otherwise it would no longer be permissible to operate the disconnectors in the feeders.

This function is called a coupler switch blocking. Each feeder sends this information to the coupler bay.

Title:Efficient Energy Automation with the IEC 61850 Standard Application Examples  – Siemens
Format:PDF
Size:2.8 MB
Pages:48
Download:Right here | Video Courses | Membership | Download Updates
Efficient Energy Automation with the IEC 61850 Standard Application Examples – Siemens
Efficient Energy Automation with the IEC 61850 Standard Application Examples – Siemens

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

2 Comments


  1. Elyonwilch C. Oyo-a
    Jun 01, 2019

    I’m glad and happy that i’ve know the latest innovations. These is very helpful to me..
    Thank you verymuch.


  2. Samson Molobeka
    Jun 13, 2018

    This is beneficial to me.Thank you!!!!.

Leave a Reply to Elyonwilch C. Oyo-a

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

four  ×    =  28

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).