Transformer Action

Transformer action depends upon magnetic lines of force (flux). At the instant a transformer primary is energized with AC, a flow of electrons (current) begins. During the instant of switch closing, buildup of current and magnetic field occurs.

Transformers Basics, Maintenance and Diagnostics
Transformers Basics, Maintenance and Diagnostics (photo credit: startest.ae)

As current begins the positive portion of the sine wave, lines of magnetic force (flux) develop outward from the coil and continue to expand until the current is at its positive peak. The magnetic field is also at its positive peak. The current sine wave then begins to decrease, crosses zero, and goes negative until it reaches its negative peak.

The magnetic flux switches direction and also reaches its peak in the opposite direction.

With an AC power circuit, the current changes (alternates) continually 60 times per second, which is standard in the United States. Other countries may use other frequencies. In Europe, 50 cycles per second is common.
Transformer action
Figure 3 – Transformer action

Strength of a magnetic field depends on the amount of current and number of turns in the winding. When current is reduced, the magnetic field shrinks. When the current is switched off, the magnetic field collapses.

When a coil is placed in an AC circuit, as shown in figure 3, current in the primary coil will be accompanied by a constantly rising and collapsing magnetic field. When another coil is placed within the alternating magnetic field of the first coil, the rising and collapsing flux will induce voltage in the second coil.

When an external circuit is connected to the second coil, the induced voltage in the coil will cause a current in the second coil. The coils are said to be magnetically coupled; they are, however, electrically isolated from each other. Many transformers have separate coils, as shown in figure 3, and contain many turns of wire and a magnetic core, which forms a path for and concentrates the magnetic flux

The winding receiving electrical energy from the source is called the primary winding. The winding which receives energy from the primary winding, via the magnetic field, is called the “secondary” winding.

Either the high- or low-voltage winding can be the primary or the secondary.

With GSUs at Reclamation powerplants, the primary winding is the low voltage side (generator voltage), and the high voltage side is the secondary winding (transmission voltage). Where power is used (i.e., at residences or businesses), the primary winding is the high-voltage side, and the secondary winding is the low-voltage side.

The amount of voltage induced in each turn of the secondary winding will be the same as the voltage across each turn of the primary winding. The total amount of voltage induced will be equal to the sum of the voltages induced in each turn.

Therefore, if the secondary winding has more turns than the primary, a greater voltage will be induced in the secondary; and the transformer is known as a step-up transformer. If the secondary winding has fewer turns than the primary, a lower voltage will be induced in the secondary; and the transformer is a step-down transformer.

Note that the primary is always connected to the source of power, and the secondary is always connected to the load.

In actual practice, the amount of power available from the secondary will be slightly less than the amount supplied to the primary because of losses in the transformer itself. When an AC generator is connected to the primary coil of a transformer (figure 4), electrons flow through the coil due to the generator voltage.

Alternating current varies, and accompanying magnetic flux varies, cutting both transformer coils and inducing voltage in each coil circuit.

Transformer primary and secondary windings
Figure 4 – Transformer primary and secondary windings

The voltage induced in the primary circuit opposes the applied voltage and is known as back voltage or back electro-motive-force (back EMF). When the secondary circuit is open, back EMF, along with the primary circuit resistance, acts to limit the primary current.

Primary current must be sufficient to maintain enough magnetic field to produce the required back EMF.

When the secondary circuit is closed and a load is applied, current appears in the secondary due to induced voltage, resulting from flux created by the primary current. This secondary current sets up a second magnetic field in the transformer in the opposite direction of the primary field.

Thus, the two fields oppose each other and result in a combined magnetic field of less strength than the single field produced by the primary with the secondary open. This reduces the back voltage (back EMF) of the primary and causes the primary current to increase.

The primary current increases until it reestablishes the total magnetic field at its original strength.

In transformers, a balanced condition must always exist between the primary and secondary magnetic fields. Volts times amperes (amps) must also be balanced (be the same) on both primary and secondary.

The required primary voltage and current must be supplied to maintain the transformer losses and secondary load.

Title:Transformers Basics, Maintenance and Diagnostics – U.S. Department of the Interior
Format:PDF
Size:865 KB
Pages:55
Download:Right here | Video Courses | Membership | Download Updates
Transformers Basics, Maintenance and Diagnostics
Transformers Basics, Maintenance and Diagnostics

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

10 Comments


  1. Alialtaher
    Jul 17, 2020

    I want a 50 or 100kva transformer that has a two-phase current without a neutral 11kv / 50Hz and a three-phase outward current of 0.4 with a neutral of 50 hz


  2. vinoth kumar
    Sep 16, 2018

    I can’t download


  3. horsfall sodieye
    Apr 17, 2018

    how can i download


  4. Somyot
    Jan 13, 2014

    Edvard, I am an engineer in this field. So, I think this is the good book for guid line to share with the people in idea “how to take care our transformer for life expansion”. This will be leading to reduce the gobal warming of this world passing the long life of a transformer. However, the file is not complete in the chapter. If you need to share like I said. please give the book in full version to light our knowledge. Finally, the people die everyday but the transfered knowledge is not die from this world. Thank you.


  5. praba
    Oct 20, 2013

    where is download link?? how can i download the pdf file pls help me…


  6. frozzty
    Feb 25, 2013

    Thanks for the documents, is really interesting and explanatory, so perhaps you could upload the missing pages?

    Thank you!


    • Edvard
      Feb 25, 2013

      You’re welcome Frozzty, glad you find it usefull! This document is as it is, I cannot add anything to it. Sorry!


      • frozzty
        Feb 25, 2013

        thanks for your welcome and thanks for your reply :)


  7. amirarya
    Feb 25, 2013

    i can”t download becas the link off download is damaged


    • Edvard
      Feb 25, 2013

      I double checked the link and it works just fine. Maybe you’re having some issues on your side.

Leave a Reply to horsfall sodieye

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

  −  two  =  one

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Courses - A hand crafted cutting-edge electrical engineering knowledge