Search

Premium Membership

Get 15% OFF on Pro Premium Plan with discount code: UX21M. Study specialized electrical engineering articles and papers in Low- and High-Voltage areas.

Home / Download Center / Electrical Engineering Books and Technical Guides / Relay control and protection guides / Circulating current scheme using IEC 61850 and relay logic for junior & graduate engineers

IEC 61850 GOOSE messages

This paper describes the implementation of a circulating current scheme that uses IEC 61850 GOOSE messages to provide automatic voltage regulation for up to four paralleled power transformers.

Circulating current scheme using IEC 61850 and relay logic for junior or graduate engineers
Circulating current scheme using IEC 61850 and relay logic for junior or graduate engineers (on photo: Feeder protection relay SEL-751 and transformer protection relay SEL -787; credit: SEL inc.)

IEC 61850 need not be applied on a substation-wide basis. There are many power system operation and control challenges that can be solved using parts of the technology outlined in the standard.

The paper is a tutorial for junior or graduate engineers to de-mystify the circulating current principle and encourage the use of IEC 61850 and relay logic to solve power system control and protection issues.

Hardware selection, scheme design, and network considerations are explored. The paper discusses lessons learned from setting and commissioning in-service solutions.

Circulating Current Between Two Transformers
Circulating Current Between Two Transformers. If two or more transformers are connected in Figure 1 – parallel, any difference in the voltage produced by the transformers generates a circulating current. The current is proportional to the voltage difference between the transformers divided by the sum of the impedances around the circulating path.

Introduction

This paper presents a control solution that uses IEC 61850 Generic Object-Oriented Substation Event (GOOSE) messages to create an automatic voltage regulator (AVR) scheme that employs circulating current principles.

The paper describes the background of IEC 61850 and some of the solutions GOOSE messaging has enabled. It also explores the requirements for operating transformers in parallel and the need for an adequate control regime.

The paper provides a tutorial on the design of a voltage regulating algorithm that uses relay logic. It develops a voltage-based scheme and adds a circulating current biasing technique to allow the parallel operation of up to four power transformers. The paper explores Ethernet networking topologies and the requirements for their successful integration into the substation environment.

Finally, the paper shares commissioning requirements and lessons learned from in-service schemes.


Background

IEC 61850

The IEC 61850 standard was first released in the latter part of the 1990s. It was adapted from earlier work by the Electric Power Research Institute (EPRI) and the Institute of Electrical and Electronics Engineers (IEEE) that defined the Utility Communications Architecture (UCA).

The IEC 61850 standard consists of a set of documents that describe the substation design, configuration, and testing for both client-server and peer-to-peer communications.

The standard defines five types of communications services. GOOSE messaging is one of the services defined by the standard and may be the most widely adopted part of the IEC 61850 protocol.

Title:Circulating current scheme using IEC 61850 and relay logic for junior or graduate engineers – Brett Hampson; Schweitzer Engineering Laboratories, Inc.
Format:PDF
Size:593 KB
Pages:15
Download:Right here | Video Courses | Membership | Download Updates
Circulating current scheme using IEC 61850 and relay logic for junior or graduate engineers
Circulating current scheme using IEC 61850 and relay logic for junior or graduate engineers

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

3 Comments


  1. Gunvant
    Mar 31, 2019

    Excellent information about practical issues in power systems


  2. Carlos Ruiz Tellez
    Sep 26, 2018

    excellent article, very interesting for people who are starting in the world of digital Substations and communication protocol IEC61850


  3. Mark Elias ugwuegbu
    Sep 25, 2018

    You guys are doing real job,keep it up

Leave a Reply to Carlos Ruiz Tellez

Tell us what you're thinking... we care about your opinion!

Electrical Engineering Courses

Learn to design electrical power and industrial automation systems through professional video courses.