Home / Download Center / Electrical Engineering Books and Technical Guides / Relay control and protection guides / Generating power plant and transmission system protection coordination

The Goal

The goal of this document is to explore generating plant protection schemes and their settings, and to provide guidance for coordination with transmission protection, control systems, and system conditions to minimize unnecessary trips of generation during system disturbances.

Generating Power Plant and Transmission System Protection Coordination
Generating Power Plant and Transmission System Protection Coordination (photo credit: think-grid.org)

Scope

This Technical Reference Document is applicable to all generators but concentrates on those generators connected at 100-kV and above.

This document includes information exchange requirements between Generator Owners and Transmission Owners to facilitate coordination between their protection schemes. This document provides a technical basis to evaluate the coordination between generator protection and transmission protection system.

The protection coordination discussed in this document applies only to situations where the specific protection functions are present and applied. There are generator protection schemes that do not include some of these functions based on the application or need.

This document is not an endorsement of using these functions; good industry guidance such as IEEE Standard C37.102, “IEEE Guide to AC Generator Protection,” and recommendations from the generator and other equipment manufacturers should take precedence as to which protection functions are applied.

904 MVA Generator Connected to a 345-kV System by Three Lines
904 MVA Generator Connected to a 345-kV System by Three Lines

Distributed Generation (DG) facilities connected to distribution systems are outside the scope of this report. Such DG protection requirements and guidance are covered by IEEE 1547 – 2003 – IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems.


Coordination Definition

For purposes of this document and as guidance to the entities, coordination is defined as the following:

Definition: – Coordination of generation and transmission protection systems (for events external to the plant), means that power plant protection and related control elements must be set and configured to prevent unnecessarily tripping the generator prior to any transmission protection and related control systems acting first, unless the generator is in jeopardy by exceeding its design limits due to operating conditions, generator system faults, or other adverse potentially damaging conditions.

Title:Power Plant and Transmission System Protection Coordination – NERC (North American Electric Reliability Corporation)
Format:PDF
Size:1.50 MB
Pages:200
Download:Right here | Video Courses | Membership | Download Updates
Power Plant and Transmission System Protection Coordination
Power Plant and Transmission System Protection Coordination

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
Black Friday Deal 💥 - Save 20% on Pro Membership Plan and all courses at EEP Academy with a discount code BLCK20

More Information

One Comment


  1. John Dadzie
    Feb 11, 2020

    Very Useful

Leave a Reply to John Dadzie

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

  ×  nine  =  ninety

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Hand-Crafted Courses
ETAP technical webinars