Search

Premium Membership

Study specialized technical articles, papers & video courses in low/high voltage areas. Save 50% on all courses at the EEP Academy with the Enterprise Plan.

Power system protection

This course represents a short overview of fundamentals of a power system protection, operating principles and relay characteristics as well as description of main switchgear components like various types of circuit breakers, CTs and PTs , relays etc.

Course on switchgears and relay protection for students
Course on switchgears and relay protection for students

Overcurrent and earth fault protection

It is customary to have two elements of overcurrent and one element of earth fault protection system in the most elementary form of protection of three phase feeders. Different types of feeders employ the overcurrent protection along with the directional relay so that proper discrimination of an internal fault is possible.

Some examples are illustrated below.


Application of directional relays to parallel feeders

It may be seen from the below given parallel feeders that the relays placed at the load side of both the lines use directional element which respond to a direction away from the busbars.

Similarly, the relays placed at the source side do not require any directional element. A similar concept of discrimination is also utilized in the below given ring main feeder and a feeder fed from both the sides.

It can be observed that relays placed near the bus connecting the sources, do not have any directional feature, where as the rest of the buses, respond to a direction always away from the source.

It is good practice to locate a fault any where among different sections of the feeders and check whether that particular section only is isolated without disrupting the power flow in other sections.

Application of directional relays to parallel feeders
Application of directional relays to parallel feeders

Pilot wire schemes for feeder protection

In differential protection scheme, the current entering at one end of the line and leaving from other end of the line is compared. The pilot wires are used to connect the relays.

Under normal working condition, the two currents at both ends are equal and pilot wires do not carry any current, keeping relays inoperative. Under an internal fault condition, the two currents at both the ends are no longer same, this causes circulating current flow through pilot wires and makes the relay to trip.

The various schemes used with this method of protection are:

  1. MerzPrice Voltage Balance System
  2. Translay Scheme Merz-Price Voltage Balance System

The figure below shows Merz-Price voltage balance system used for the three phase feeders.

Merz-Price voltage balance system used for the three phase feeders
Merz-Price voltage balance system used for the three phase feeders

Under normal condition, current entering the line at one end is equal to current leaving from the other end. Therefore, equal and opposite voltages are induced in the secondaries of CTs. at the two ends resulting in no current flow, through the relay.

Under fault condition, two currents at the two ends are different. Thus the secondary voltages of both the end CTs differ from each other. This circulates a circulating current through the pilot wires and the relays.

Thus the relays trip the circuit breakers to isolate the faulty section.

Title:Course on switchgears and relay protection for students – Mr. S.Vijay, Assistant Professor At Department Of Electrical And Electronics Engineering (Sasurie College Of Engineering, Vijayamangalam)
Format:PDF
Size:2.30 MB
Pages:94
Download:Right here | Video Courses | Membership | Download Updates
Course on switchgears and relay protection for students
Course on switchgears and relay protection for students

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

2 Comments


  1. donRARE
    Sep 05, 2020

    I would assume this is based on classical relay use. Nowdays, would you not use current sensing transformers and electronic monitoring and disconnection ?


  2. Henry
    Dec 19, 2018

    Excelente información, me gustaría obtener más datos

Leave a Reply to Henry

Tell us what you're thinking... we care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

  +  36  =  forty

EEP Academy Video Courses

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning.