Active Harmonic Conditioners And Unity Power Factor Rectifiers
Active Harmonic Conditioners And Unity Power Factor Rectifiers

Abstract

Electric loads are becoming increasingly non-linear in the industrial, tertiary and even household sectors. These loads absorb non-sinusoidal currents which, under the effect of circuit impedance, distort the purely sinusoidal voltage waveform. This is what is known as harmonic disturbance of power networks, currently a cause for concern as it gives rise to serious problems.

We recommend that harmonic non-specialist readers begin by reading the appendix where they will find the basic concepts required to understand the various standard and new solutions to limit or combat harmonics.

Not only the characteristic quantities, but also the non linear equipment, influence of the sources and disturbing effects of harmonics need to be known.

Last but not least, standards lay down levels of compatibility, i.e. the maximum permissible levels. The purpose of this “Cahier Technique” is to describe the active harmonic conditioners. This attractive, flexible and self-adaptive solution can be used in a wide variety of cases to complete or replace other solutions.

However chapter 1 of this “Cahier Technique” will review other “traditional” solutions which should also be taken into consideration.

AUTHOR: Schneider Electric experts| Eric BETTEGA, Jean Noël FIORINA

Title:Active harmonic conditioners and unity power factor rectifiers – Schneider Electric
Format:PDF
Size:318 KB
Pages:36
Download:Right here | Video Courses | Membership | Download Updates
Active Harmonic Conditioners And Unity Power Factor Rectifiers
Active Harmonic Conditioners And Unity Power Factor Rectifiers

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

2 Comments


  1. mostafa fayezizadeh
    Feb 27, 2018

    these subjects are very useful for me

    thanks so much


  2. rasool sharifi
    Jan 26, 2013

    Hi sorry but i think that links of book is ….lost…..or forbidden

Leave a Reply to mostafa fayezizadeh

Tell us what you're thinking... we care about your opinion!

EEP Academy Video Courses

The learning platform for LV/MV/HV electrical engineers. Learn from experienced engineers and sharpen up your knowledge.