Search

Premium Membership ♕

Limited Time Offer: Save 15% on PRO Plan with discount code: LRN15 and study specialized LV/MV/HV technical articles and studies.

MV Network Design

MV Network Design Book, prepared by Schneider Electric gives a great technical knowledge of MV network design and correct devices selection intended for medium voltage equipment and network designers.

MV Network Design Book With Exercises and Answers
MV Network Design Book With Exercises and Answers by Schneider Electric

This guide helps you to carry out the various calculations required to define and determine network characteristics, substation equipment dimensions and provides useful information enabling you to design your MV switchboard and other substation devices.

Exercise sections and answers //

  1. MV substation architectures
  2. MV substation architectures
  3. Industrial C13-200 MV substation
  4. Max. distance between surge arrester and MV equipment
  5. Calculation of MV cable cross-section
  6. Calculation of Isc
  7. CT s for MV metering
  8. CT s for MV protection
  9. Earth-fault relay settings
  10. Capacitors

Exercise 1 – MV substation architectures

To define //

  1. Type of LV or MV metering
  2. Architecture and choice of cubicles
  3. Type and rating of fuse that protects the transformer

Inputs //

  • Consumer substation on energy supplier loop: 20kV
  • 1 800kVA transformer with 20kV/400V secondary
  • Short-circuit power 250 MVA

Answers and chosen substation equipment //

  • 800 kVA with 20 kV = 23A < 45A
    OK for LV metering
  • 800 kVA with 410V = 1127A < 2000A
  • 800 kVA < 1250 kVA
  • MV Isc 20kV = 250MVA / 20kV / 1.732 = 7.2 kA rms
    OK for standard equipment 24 KV 12.5 kA
  • 800 kVA 20 kV transformer, UTE standard,
    43A Solefuse chosen fuse rating
Chosen MV substation architecture
Chosen MV substation architecture

Title:MV Network Design Answer and Exercise Book by Schneider Electric
Format:PDFs
Size:100 KB + 170 KB
Pages:31 + 37
Download 1:Right here
Download 2:Right here | Video Courses | Membership | Download Updates
MV Network Design - Answer and Exercise Book
MV Network Design – Answer and Exercise Book by Schneider Electric

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

14 Comments


  1. Edrisa Conteh
    Jun 01, 2023

    Thank you for sharing this opportunity and I am glad to connect to your esteemed organization.


  2. Edrisa Conteh
    Jun 01, 2023

    I am really interested


  3. Habia
    Dec 26, 2020

    it is necessary to insert in the diagram an inverter between the transformers and the generator


  4. Kishor Bordhan
    Apr 21, 2020

    It’s a very helpful information. Thank You!


    • Edvard
      Apr 21, 2020

      You’re welcome Kishor, I’m glad you find it useful.


  5. Michael
    Apr 14, 2019

    I think it’s a very helpful information


  6. Armando Medel Trujillo
    Dec 08, 2018

    Excelente práctica y aplicable información


  7. Muhammad Ismail Shaikh
    Sep 24, 2018

    Thanks, Right time right Article. Now I am working on big project there have 8 substation, I verified that design with the help of this Exercise .


  8. Enoka
    Sep 23, 2018

    Thanks it very useful


  9. Mahdi
    Sep 23, 2018

    Thanks, Really useful.


  10. julioabelotarolaluna
    Oct 10, 2017

    Me interesa este tipo de ejemplos sobre arquitectura de una sub-estacion MV, pues es muy ilustrativo.


  11. Felix
    May 27, 2017

    Valuable information! Thanks for sharing it!


  12. Zana
    Aug 29, 2016

    Very helpful information, thank you


  13. Jason
    May 02, 2016

    Where is the Design Guide? The only downloads I see are for the exercise book and the answer book, but not the actual guide.

Leave a Reply to Muhammad Ismail Shaikh

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

three  ×  1  =  

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Courses - A hand crafted cutting-edge electrical engineering knowledge