Home / Download Center / Electrical Engineering Books and Technical Guides / Schneider Electric MV/LV Tehnical Guides and Studies

Schneider Electric Experience

This section is a collection of documents intended for engineers and technicians, people in the industry who are looking for more in-depth information in order to complement that given in product catalogs. Furthermore, Schneider Electric’s guides, papers and “Cahiers Techniques” are often considered as very helpful “tools” for training courses.

Schneider Electric Cahiers Techniques – A collection of documents intended for engineers and technicians
Schneider Electric Cahiers Techniques – A collection of documents intended for engineers and technicians

Schneider Electric provides knowledge on new technical and technological developments in the electrotechnical field and electronics. They also provide a better understanding of various phenomena observed in electrical installations, systems, and equipment.

Each “Cahier Technique” provides an in-depth study of a precise subject in the fields of electrical networks, protection devices, monitoring and control, and industrial automation systems.


About Schneider Electric

Schneider Electric SA. The Group’s principal activities are electricity and automation management. The Group operates under three major segments: electrical distribution, automation and control and secured energy.

Under Electricity distribution, the company offers electrical products such as circuit breakers, switches, safety lighting, prefabricated busbar trunking, modular switchgear, power line carrier communication networks, and voice-data-image solutions. Under Automation and Control, Schneider offers products to control and supply power to equipment such as contactors, overload relays, soft starters, speed drives, sensors, and operator terminals.

Schneider Electric operates mainly in Europe, Asia Pacific, and North America. In 2008, Schneider Electric acquired ECP Tech Services, Marisio, Wessen, RAM Industries, Xantrex, DMS and American Power Conversion (APC).

In past 40 years Schneider Electric released over 70 technical publications related to electricity and automation, and these publications are listed in this section.

Browse guides and studies

Note that all documents in this section are free to download. Navigate through sub-pages to discover all documents.

Power supply of lighting circuits

A source of comfort and productivity, lighting represents 15% of the quantity of electricity consumed in industry and 40% in buildings. The quality of the lighting (light stability and continuity of service) depends on the quality of the electrical energy… Read more

Sep 26, 2010

Power Quality

One of the properties of electricity is that some of its characteristics depend not only on the electricity producer/distributor but also on the equipment manufacturers and the customer. The large number of players combined with the use of terminology and… Read more

Sep 26, 2010

Overvoltages and insulation coordination in MV and HV

Insulation coordination is a discipline aiming at achieving the best possible technico-economic compromise for protection of persons and equipment against overvoltages, whether caused by the network or lightning, occurring on electrical installations. It helps ensure a high degree of availability… Read more

Sep 26, 2010

Neutral earthing in an industrial HV network

HV electrical networks can be earthed in different ways. This document analyzes the constraints imposed by the different parameters of the installation (overvoltages, network, receivers) and calculates the fault currents. Different protection modes are described along with the settings and… Read more

Sep 26, 2010

MV public distribution networks throughout the world

In a country, the Transmission and Public Distribution networks ensure the transfer of electrical energy from points of production to consumer units. The points of production are power stations that generate electrical energy from various primary energy sources (nuclear, hydro-electric,… Read more

Sep 26, 2010

LV surges and surge arresters LV insulation co-ordination

Low voltage insulation co-ordination consists of matching the surge levels that may appear on an electrical network (or installation) with the surge withstand of the industrial or domestic equipment that it supplies, bearing in mind the possibility of including surge… Read more

Sep 26, 2010

LV protection devices and variable speed drives

The purpose of this “Cahier Technique” is to explain the specific phenomena observed in LV installations when there is an overload or electrical fault in circuits equipped with variable speed drives. Various recommendations are given to ensure that persons and… Read more

Sep 26, 2010

LV circuit-breaker

The energy sources for electrical installations are AC generators and transformers. All these generators, however perfect, have an internal impedance which has two major effects: in normal operating conditions, this impedance causes voltage to drop from no-load condition to bring… Read more

Sep 25, 2010

LV breaking by current limitation

This “Cahier Technique” provides a simple introduction to the principles of low voltage current limitation, a technique developed by Merlin Gerin in direct current as early as 1930 and in alternating current in 1954. It simplifies understanding of the advantages… Read more

Sep 25, 2010

Lightning and HV electrical installations

The goal of this «Cahier Technique» publication is to: present an overview of lightning phenomena and their effects on electrical installations, present currently available means to protect installations and limit detrimental effects, discuss problems concerning continuity of service, indicate the… Read more

Sep 25, 2010

Inverters and harmonics (case studies of non-linear loads)

Static UPS are virtually perfect electric generators. They are highly reliable and, by nature, ensure (within the performance limits of the battery) the uninterrupted availability of electric power. As regards electrical characteristics, the inverter (which constitutes the UPS generator) possesses… Read more

Sep 25, 2010

Introduction to dependability design

Equipment failures, unavailability of a power supply, stoppage of automated equipment and accidents are quickly becoming unacceptable events, be it to the ordinary citizen or industrial manufacturers. Dependability and its components: reliability, maintainability, availability and safety, have become a science… Read more

Sep 25, 2010

Intelligent LV switchboards

In all buildings, regardless of the activity carried out inside, the distribution of electrical power must today satisfy ever-increasing needs for dependability and efficiency. Energy must be available not only to ensure the comfort and safety of users, but also… Read more

Sep 25, 2010

14 Comments


  1. Syed Umer Moiz, 1277 Clark Blvd Milton Ontario L9T 6L1, Canada
    Feb 13, 2021

    Very helpful


  2. Vinayakam Balachandran
    Nov 05, 2019

    I have been associated with the design & manufacture of High Current & High Voltage Busbars for more than 45 years. I am in the process of writing a book titled “An Introduction to Busbar Systems” and expect it to be ready for publication by this year end.

    One of the chapters in the book is devoted to IMPEDANCE. I would like to seek permission from SCHNEIDER to capture information available in “Cashier technique no. 83” to be incorporated in the book. Needless to state that any of the content reproduced in the book will acknowledge the source.

    I would appreciate a positive response at your earliest convenience. Please feel free to contact me for any specific information that you may desire in connection with the above request.

    Best regards

    Sincerely yours

    Balachandran


  3. Senan
    Jul 12, 2019

    Thanks for good information . Very very helpful


  4. C.SUBRAMANIAN NAMBISAN
    Aug 28, 2018

    Many Thanks to you and you for compiling these articles which are so informative and useful.

    CS Nambisan


  5. talal abu sharkh
    Aug 13, 2018

    Thanks so much


  6. Nzuya Evans
    Nov 01, 2017

    What is the procedure of downloading your article please help coz I hv attempted several tims but in vain…otherwise I salute you


  7. salah doukhane
    Nov 14, 2016

    merci beaucoup.


  8. Anthony Bor
    Mar 31, 2016

    The documents in this website are fascinating and very help full I would however like to learn more on Earthing of DC supply system now that the world is turning to sustainable energy power


  9. Thabang Molelle
    Sep 23, 2015

    I ma studying electrical engineering at French South African Schneider Electric Education Center. I use Schneider Electric components they are very interesting and eventually making life simple. Hope i will, one get employed at Schneider Electric.


  10. Mohamed Hendy
    Dec 24, 2013

    Thank u


  11. MIRJANI.KH
    May 05, 2011

    As you know the Schneider group make one of the best relay,s “sepam series” and also other kind of protection. so a book or a paper about protection will be very useful


    • Edvard
      Jun 13, 2011

      Yes indeed! SEPAM is good protection relay with bunch of possibilities. However, maybe I will publish some technical article about SEPAM relays with info and catalogue or paper for download.

      Thanks fot the tip Mirjani!

      BR


      • hobo
        Jul 24, 2012

        Yes,I support Mirjani.SEPAM Relays,from my experience are one of teh best relays I have ever seen.


      • The Vinh
        Jun 03, 2015

        I am currently working at Schneider Electric.
        All documents on this website are very interesting and helpful with me.
        For the SEPAM relay, If you need any document please let’s me know.

Leave a Comment

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.