Schneider Electric Experience

This section is a collection of documents intended for engineers and technicians, people in the industry who are looking for more in-depth information in order to complement that given in product catalogs. Furthermore, Schneider Electric’s guides, papers and “Cahiers Techniques” are often considered as very helpful “tools” for training courses.

Schneider Electric Cahiers Techniques – A collection of documents intended for engineers and technicians
Schneider Electric Cahiers Techniques – A collection of documents intended for engineers and technicians

Schneider Electric provides knowledge on new technical and technological developments in the electrotechnical field and electronics. They also provide a better understanding of various phenomena observed in electrical installations, systems, and equipment.

Each “Cahier Technique” provides an in-depth study of a precise subject in the fields of electrical networks, protection devices, monitoring and control, and industrial automation systems.


About Schneider Electric

Schneider Electric SA. The Group’s principal activities are electricity and automation management. The Group operates under three major segments: electrical distribution, automation and control and secured energy.

Under Electricity distribution, the company offers electrical products such as circuit breakers, switches, safety lighting, prefabricated busbar trunking, modular switchgear, power line carrier communication networks, and voice-data-image solutions. Under Automation and Control, Schneider offers products to control and supply power to equipment such as contactors, overload relays, soft starters, speed drives, sensors, and operator terminals.

Schneider Electric operates mainly in Europe, Asia Pacific, and North America. In 2008, Schneider Electric acquired ECP Tech Services, Marisio, Wessen, RAM Industries, Xantrex, DMS and American Power Conversion (APC).

In past 40 years Schneider Electric released over 70 technical publications related to electricity and automation, and these publications are listed in this section.

Browse guides and studies

Note that all documents in this section are free to download. Navigate through sub-pages to discover all documents.

Integration of local power generation

Engine driven alternating current generator sets are often used in remote industrial sites as a prime source of electrical energy. They are also extensively used in both industry and commercial buildings as a source of back-up power. This cahier technique… Read more

Sep 25, 2010

HV industrial network design

Faced with increasingly fierce competition, industrialists must employ highly rigorous management and their production facilities must have a high level of availability. Electrical networks supply the energy required to run the production facilities. The provision of a continuous power supply… Read more

Sep 25, 2010

High availability electrical power distribution

The objective of this «Cahier Technique» is to explain to electrical installation designers how to design electrical power distribution systems that fulfil the objective of continuous voltage supply across the feeder terminals. In other words: how to master power availability… Read more

Sep 25, 2010

Harmonics upstream of rectifiers in UPS

UPS, like most static converters draw energy from an A.C. mains network through rectifiers. Often, these rectifiers fitted with thyristors are generators of harmonics. Merlin Gerin, manufacturers of UPS equipment are well acquainted with this problem and consequently have decided… Read more

Sep 25, 2010

Harmonic disturbances in networks and their treatment

Electricity is generally distributed as three voltage waves forming a 3-phase sinusoidal system. One of the characteristics of such a system is its waveform, which must always remain as close as possible to that of a pure sine wave. If… Read more

Sep 25, 2010

Fuzzy logic

Initially a theory, today fuzzy logic has become an operational technique. Used alongside other advanced control techniques, it is making a discrete but appreciated appearance in industrial control automation systems. Fuzzy logic does not necessarily replace conventional control systems. Rather… Read more

Sep 25, 2010

From current transformers to hybrid sensors, in HV

Proper operation and safety of electrical power distribution networks, from the electrical power station right through to the point of use, is ensured by protection and control/monitoring equipment. This equipment requires permanent knowledge of the two fundamental electrical values, namely… Read more

Sep 25, 2010

Ferroresonance

Ferroresonance is a non-linear resonance phenomenon that can affect power networks. The abnormal rates of harmonics and transient or steady state overvoltages and overcurrents that it causes are often dangerous for electrical equipment. Some unexplained breakdowns can be ascribed to… Read more

Sep 25, 2010

Fault arcs on busbar sets and switchboards

These result from a gradual decrease in the inter-phase or inter-phase to ground insulation resistance. This decrease can be the result of deposits which, subsequent to exceptional humidity conditions, can result in the formation of a superficial resistance bridge such… Read more

Sep 25, 2010

Energy-based discrimination for low-voltage protective devices

The purpose of this “Cahier Technique” publication is to present the new energy-based discrimination technique that ensures tripping discrimination between protective devices during a short-circuit. Both simpler and more effective than standard discrimination techniques, it has been implemented on the… Read more

Sep 25, 2010

Energy savings in buildings

Irrespective of the building to be built or managed, there is a need for solutions to control energy consumption. This holds true throughout the world for all types of buildings, in the industrial, residential or service sectors. Before designing or… Read more

Sep 25, 2010

Enclosures and degrees of protection

It is not sufficient that a piece of equipment fulfils the functional requirements assigned to it. It also has to be protected against possible adverse external influences, and likewise to ensure that it is not harmful to the user or… Read more

Sep 24, 2010

EMC – electromagnetic compatibility

For all electrotechnical equipment, EMC must be considered right from the initial design phase and the various principles and rules carried on through to manufacture and installation. This means that all those involved, from the engineers and architects that design… Read more

Sep 24, 2010

Electronic starters and variable speed drives

The most common way of starting asynchronous motors is directly on the line supply. This technique is often suitable for a wide variety of machines. However, it sometimes brings with it restrictions that can be inconvenient for some applications, and… Read more

Sep 24, 2010

14 Comments


  1. Syed Umer Moiz, 1277 Clark Blvd Milton Ontario L9T 6L1, Canada
    Feb 13, 2021

    Very helpful


  2. Vinayakam Balachandran
    Nov 05, 2019

    I have been associated with the design & manufacture of High Current & High Voltage Busbars for more than 45 years. I am in the process of writing a book titled “An Introduction to Busbar Systems” and expect it to be ready for publication by this year end.

    One of the chapters in the book is devoted to IMPEDANCE. I would like to seek permission from SCHNEIDER to capture information available in “Cashier technique no. 83” to be incorporated in the book. Needless to state that any of the content reproduced in the book will acknowledge the source.

    I would appreciate a positive response at your earliest convenience. Please feel free to contact me for any specific information that you may desire in connection with the above request.

    Best regards

    Sincerely yours

    Balachandran


  3. Senan
    Jul 12, 2019

    Thanks for good information . Very very helpful


  4. C.SUBRAMANIAN NAMBISAN
    Aug 28, 2018

    Many Thanks to you and you for compiling these articles which are so informative and useful.

    CS Nambisan


  5. talal abu sharkh
    Aug 13, 2018

    Thanks so much


  6. Nzuya Evans
    Nov 01, 2017

    What is the procedure of downloading your article please help coz I hv attempted several tims but in vain…otherwise I salute you


  7. salah doukhane
    Nov 14, 2016

    merci beaucoup.


  8. Anthony Bor
    Mar 31, 2016

    The documents in this website are fascinating and very help full I would however like to learn more on Earthing of DC supply system now that the world is turning to sustainable energy power


  9. Thabang Molelle
    Sep 23, 2015

    I ma studying electrical engineering at French South African Schneider Electric Education Center. I use Schneider Electric components they are very interesting and eventually making life simple. Hope i will, one get employed at Schneider Electric.


  10. Mohamed Hendy
    Dec 24, 2013

    Thank u


  11. MIRJANI.KH
    May 05, 2011

    As you know the Schneider group make one of the best relay,s “sepam series” and also other kind of protection. so a book or a paper about protection will be very useful


    • Edvard
      Jun 13, 2011

      Yes indeed! SEPAM is good protection relay with bunch of possibilities. However, maybe I will publish some technical article about SEPAM relays with info and catalogue or paper for download.

      Thanks fot the tip Mirjani!

      BR


      • hobo
        Jul 24, 2012

        Yes,I support Mirjani.SEPAM Relays,from my experience are one of teh best relays I have ever seen.


      • The Vinh
        Jun 03, 2015

        I am currently working at Schneider Electric.
        All documents on this website are very interesting and helpful with me.
        For the SEPAM relay, If you need any document please let’s me know.

Leave a Comment

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.