Search

Black Friday Deal💥

Save 20% with a coupon BLCK20 on PRO Membership Plan and all courses at the EEP Academy! Learn from experienced engineers!

MV switchgear busbars

If the switching principle has not yet been defined during network planning or in accordance with operator specifications, some general aspects should be taken into account to help reach a decision of a right medium voltage switchgear.

Medium voltage switchgear application guide (selection, switching duties, configurations)
Medium voltage switchgear application guide (selection, switching duties, configurations)

And these are:

Selection variable: single / double busbars, bus section panel, bus section panel / transfer panel with switch or circuit-breaker or bus coupler unit (with double busbar).

Key influencing factors for the right decision of a MV switchgear are: line structure, line protection, tripping times and selectivity, reserves / availability, switchover time, operating procedures, in-plant generation, emergency supply or power quality (unstable loads).


MV switchgear with single busbars

A single busbar is suitable for most supply duties. In systems with a higher number of feeder circuits, the busbars can be sub-divided into sections each with their own infeed. In this way, each section can potentially draw a reserve supply from an adjacent section.

Single busbar switchgear has the following benefits:

  1. it is completely transparent in all switching states;
  2. as a result, it is easy to use if network failures need to be rectified urgently, which greatly reduces the risk of switching faults;
  3. if switchovers caused by faults need to be carried out, only the circuit-breakers need to be operated.

If the wrong circuit-breaker is operated inadvertently, this will not affect safety of the switchgear because circuit-breakers can make or break all load and short-circuit currents, even during earth fault and under any other fault conditions.


MV switchgear with double busbars

For technical or contractual reasons, some requirements can only be properly fulfilled by means of double busbars, for example if:

Example #1 – If two (or more) infeeds must always be operated separately (e.g. infeeds from different public utility companies or the strict separation of in-plant generation and the public network);

Example #2 – If loads can interfere with the power quality when causing voltage fluctuations or flickers, and other equipment is sensitive to those interferences.

Non-sensitive loads – depending on the load status they should be switched to either the stable or the unstable busbar.

Example #3 – If loads of different importance need to be distributed across “safe” and “less safe” busbars (i.e. busbars with different requirments on the availability);

Example #4 – If a network must be divided into two sub-networks due to the limited short-circuit strength of the installed equipment. Switchovers permit to balance fluctuating load current consumption.

Design alternatives of double busbar arrangements
Figure 1 – Design alternatives of double busbar arrangements

Design of double busbars

The lifetime of a disconnector plays an important role for double busbar switchgear. If frequent switchovers are required, disconnectors should not be integrated in the switchover process due to their relatively short operating cycle lifetime.

The average mechanical endurance of a disconnector (drawout unit or truck) is 1000 or 2000 operating cycles, corresponding with classes M0 and M1 (IEC 62271-102).

Because of this low endurance – in comparison to circuit-breakers, not every design of double busbar switchgear is suitable for frequent busbar switchovers. A version with two circuit-breakers that switch between the busbars is more suitable.

Only the designs B1 and B2 suit the requirements for frequent busbar switchover. Only the circuit-breakers are operationally switched, the disconnectors are opened only for maintenance or work purposes.

In contrast to this, the classic double busbar design (A) is less suitable since every busbar switchover implies to operate the disconnectors.

Title:Medium voltage switchgear application guide (selection, switching duties, configurations) – Dipl. Ing. Ansgar Müller at Siemens
Format:PDF
Size:1.50 KB
Pages:135
Download:Right here | Video Courses | Membership | Download Updates
Medium voltage switchgear application guide (selection, switching duties, configurations)
Medium voltage switchgear application guide (selection, switching duties, configurations)

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
Black Friday Deal 💥 - Save 20% on Pro Membership Plan and all courses at EEP Academy with a discount code BLCK20

More Information

3 Comments


  1. HM
    Sep 20, 2022

    Thank You Sir, Thank You So Much.


  2. Jorge Torrico
    Jul 21, 2019

    Thank you for all information available for electrical engineers, valuable information to teach all the users of the EEP Electrical Engineering Portal.
    Best Regards

    Jorge Torrico

Leave a Reply to HM

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

fifty four  +    =  sixty four

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Hand-Crafted Courses
ETAP technical webinars