Search

Cyber Monday Deal💥

Save 20% with a coupon CYBM20 on PRO Membership Plan and 30% on courses at EEP Academy! Learn from experienced engineers!

Home / Download Center / Electrical Engineering Books and Technical Guides / Siemens Basics of Energy and Automation Guides

Energy and Automation

Introduction, Motors and Control

Besides some outstanding books and guides, as one of the world leaders in industry and automation, Siemens has released these 18 books ‘Basics of energy and automation’ related to electricity in general, motors and control, power distribution, etc. Siemens A.G. is Europe’s largest electrical and electronics company, producing over 50,000 products manufactured at 400 sites in 40 countries.

SIEMENS - Basics of Energy and Automation: Introduction, Motors & Control
SIEMENS – Basics of Energy and Automation: Introduction, Motors & Control

Referring to the Siemens history of achieving success through well engineered refinements of other people’s inventions, one Fortune analyst noted that “second is best” might well serve as Siemens’ motto. But opportunism is not the only interesting facet of Siemens’ history, which is also a story of a long family tradition and intimate involvement with some of the most important events of the 19th and 20th centuries.

Siemens and Halske was founded in Berlin in 1847 by Werner Siemens and J. G. Halske to manufacture and install telegraphic systems. Siemens, a former artillery officer in the Prussian army and an engineer who already owned a profitable patent for electroplating, was the driving force behind the company and remained so for the rest of his life.

Browse books and guides

Note that all documents in this section are free to download. Navigate through sub-pages to discover all documents.

The basics of low voltage circuit breakers

Current flow in a conductor always generates heat. The greater the current flow, the hotter the conductor. Excess heat is damaging to electrical components and conductor insulation. For that reason,… Read more

Sep 27, 2010

The basics of low voltage circuit breakers

The basics of busway distribution systems

A distribution system is a system that distributes electrical power throughout a building. Distribution systems are used in every residential, commercial, and industrial building. Distribution systems used in commercial and… Read more

Sep 27, 2010

Basics of busway distribution systems

Basics of Sensors

One type of feedback frequently needed by industrial-control systems is the position of one or more components of the operation being controlled. Sensors are devices used to provide information on… Read more

Sep 27, 2010

The Basics of Motor Control Centers (MCCs)

Power distribution systems used in large commercial and industrial applications can be complex. Power may be distributed through switchgear, switchboards, transformers, and panelboards. Power distributed throughout a commercial or industrial… Read more

Sep 27, 2010

Basics of Motor Control Centers - SIEMENS (on photo: New Motor Control Center and power distribution board up to 7000 amperes)

Basics of DC Drives

A thyristor bridge is a technique commonly used to control the speed of a DC motor by varying the DC voltage. Examples of how a DC rectifier bridge operates are… Read more

Sep 27, 2010

The basics of three-phase AC motors

AC motors are used worldwide in many applications to transform electrical energy into mechanical energy. There are many types of AC motors, but this course focuses on three-phase AC induction… Read more

Sep 27, 2010

The basics of AC motor

The Basics Of AC Drives

Totally Integrated Automation (TIA) is more than a concept. TIA Automation is a strategy developed by Siemens that emphasizes the seamless integration of automation products. The TIA strategy incorporates a… Read more

Sep 27, 2010

Basics of AC Drives - SIEMENS

Basics of Electrical Products

The objective of this course is to provide a high-level overview of the products of Siemens Energy & Automation (SE&A) with emphasis on those products sold by our channel partners…. Read more

Sep 27, 2010

7 Comments


  1. Hendrik van Niekerk
    Feb 15, 2022

    Excellent, just interested to provide you with Switchboard Manufacturing Quotation, seeing that there is a market for Solar as well. Greetings from Plestech.


  2. Deochandra Kumar
    Dec 23, 2019

    Dear sir…
    Plz. Give notes on DG Set


  3. Chitha Ajayudu
    Nov 18, 2018

    How can i download file in pdf


    • ABDULLAH KHOUAZEM
      Dec 15, 2018

      you just need to open the site via the computer . because is’nt supported on mobile .
      best regard .


  4. Shivshankar jaiswal
    Apr 26, 2018

    Wanted to learn Solar panel execution


  5. José Jamal
    May 18, 2017

    I am very pleased to have access to these articles, they are surely going to improve my understanding of the products as well as fundamental principles behind them. I have warked with Siemens pruducts during an intership in one of major hydro power plants in Moçambique.


  6. Vilas Pathak
    Sep 07, 2015

    I am Siemens India Product & worked 17 years, I appreciate the Technical Articles as they are very valuable & informative to contribute in Engineering Decisions.

Leave a Reply to Shivshankar jaiswal

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

8  ×    =  eight

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Hand-Crafted Courses
ETAP technical webinars