Home / Download Center / Electrical Software Reviews / Calculate Bus Bar Size and Voltage Drop (Spreadsheet)
Calculate Bus Bar Size and Voltage Drop
Calculate Bus Bar Size and Voltage Drop (MS Excel Spreadsheet)

Busbar voltage drop calculation

  • Calculate Voltage Drop for  Bus Bar
  • Select Size of Bus Bar for particular Load
  • Enter Your Sub Panel Details like Load,Line Length
Software:Calculate Bus Bar Size and Voltage Drop
Version:22.8.2012 New
Developer:Jignesh Parmar
Size:56 Kb
Price:Free
Download:Right here | Video Courses | Membership | Download Updates

Calculate Bus Bar Size and Voltage Drop

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

34 Comments


  1. mahmoud fawaz
    Nov 30, 2014

    Hi. How to calculate the drop voltage for 25mm2 cable three phaze +earth . 350m 4 A


  2. RJ Ordonez
    Sep 30, 2014

    there’s no unit for power on the spread sheet. is it in kva or kw? thanks!


  3. Lele
    Aug 18, 2014

    Dear EEP
    Do I have to subscribe to every download or technical article I need?
    Thank you
    Lele


  4. Sagar Jadhav
    Jul 27, 2014

    bus bar formula


    • ajit bhatavkar
      Aug 08, 2014

      Pls give me my email id bus bar formula

      Regad
      Ajit


  5. Sagar Jadhav
    Jul 27, 2014

    Dear sir,
    I ask you what is the bus bar calculation formula?


  6. sohel
    Jun 26, 2014

    In case of Busbar voltage drop calculation you take Resistance=0.005 ohm and reactance=0.011 ohm . what is the reference of these values. have any international code ? also how can i get a cable resistance and reactance ?


  7. Marvin
    Feb 15, 2014

    Very useful..Thank you very much..


  8. kakamta
    Nov 01, 2013

    thanks.but i don’t understand the way to calculation. please help?


  9. m.taqi
    Oct 25, 2013

    thanks


  10. Ronald Acuavera
    Oct 09, 2013

    please advise and calculate, i have 5x1250Amps,.8pf, 220v gensets, synch to a common busbar, and two outgoing CB’s of 2500A, what will be the main busbar rating.


  11. NAGARAJ123
    Jun 19, 2013

    IN BUSBAR TRUNKING SYSTEM HOW DO YOU CALCULATE THE KA RATING OF THE BUSBAR. FOR EXAMPLE IF CUSTOMER ASKS US TO GIVE 50KA WITH 50x10mm ALLUMINIUM OR COPPER BUSBAR WHAT IS THE FORMULA WE HAVE TO APPLY PLEASE SOME ONE WHO KNOWS ABOUT HIS GUIDE ME


    • Edvard
      Jun 19, 2013

      Customer normally shouldn’t ask you this, but to tell you the ratings of loads, so you can calculate the CBs in incomers and outgoing cubicles, as well as rating of main horizonal busbars. When you have all these information, you can calculate short curcuit withstand current on busbars.


  12. Eng. Bo.7sn
    May 27, 2013

    I entered the results but I didn’t know what is sin(phi) so i put it =0
    and the results below:
    ——————————————-
    Selected BusBar is Correct
    3.92 (Within Limit)
    ———————————————
    What is the size of the bus bar ?


  13. yaqob
    Apr 24, 2013

    thank you for this great website
    but unfortunately I couldn’t download the excel calculation files! what should I do?


  14. sazali
    Mar 11, 2013

    thank a lot for all notes had published in this portal……


  15. pankajbhai Trivedi
    Jan 16, 2013

    Thanks for my registration.
    Pl. tell me How/D.G set automatically start when mains supply fails.


    • Naheem
      Dec 26, 2018

      By a relay called LVM(low voltage monitor), it will provide NO/NC contact to DG to start/stop

Leave a Comment

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

eighteen  ⁄    =  two

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Courses - A hand crafted cutting-edge electrical engineering knowledge