Voltage drop spreadsheet

The following voltage drop calculations were all based on the resistance values in Table 8 Chapter 9 of NEC (National Electrical Code). This spreadsheet only considers voltage drop.

Voltage Drop Calculations
Voltage Drop Calculations

Many other factors affect wire size. Please refer to entire NEC when sizing wire. Spreadsheet has three sheets beside main one with calculations:

  • Printable VD calculations
  • Printable Table Parallel wires
  • Printable Table 310-16
Software:Voltage Drop Calculator – Albany Technical College
Version:28.8.2004
Developer:Albany Technical College
Size:545 kB
Price:
Download:Here 🔗 (Get Premium Membership) | Video Courses | Download Updates
Voltage drop calculations
Voltage drop calculations

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

7 Comments


  1. TANZEEM KHAN
    Jul 07, 2021

    Gentlemen,
    If i am laying a DC cable of 200 meter from UPS to the main load (Battery charger), in that case how can i calculate my voltage drop for this cable. As per my knowledge DC power has no polarity and less losses with no P.F consideration compared to AC power. So voltage drop will it be applicable here if so how please support….


  2. pipat
    Jan 22, 2020

    I need the maximum power supply length of each circuit


  3. Amr Ahmed
    Dec 04, 2019

    thank you


  4. dessouky samak
    Nov 21, 2019

    l need change voltage please
    vaiable voltage


  5. Dharmendra
    Feb 12, 2017

    The formula for minimum voltage drop is not correct.how is possible for 240v supply and 228v drop


  6. Huned
    Dec 29, 2012

    The derating factors need to be included as a part of installation, also need to check for motor [running / starting] application.


  7. dsaint
    Nov 26, 2012

    Has anyone updated this program? I’ve been using it for a while and really like the way it works, but I’d love to have it updated for NEC 2008 & 2011..

Leave a Reply to TANZEEM KHAN

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

  −  four  =  four

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Courses - A hand crafted cutting-edge electrical engineering knowledge