Muhammad Kashif

Electrical Engineer and Author at EEP

Muhammad Kashif

– Profile –

Muhammad Kashif Shamshad is an Electrical Engineer and has more than 17 years of experience in Project Management, operation & maintenance, erection, testing, and commissioning of Power Plant, GIS, and AIS high voltage substations ranging up to 500 kV –he has more than 10 year’s experience is with Siemens Saudi Arabia.

He completed over 20 high voltage substation projects, Project Management, Operation & Maintenance of Substation & Power plants in Pakistan and Saudi Arabia for different electric utilities including Saudi Electricity Company (SEC), Saudi Aramco, SABIC, Marafiq, National Transmission & Dispatch Company (NTDC), WAPDA, and K-Electric.

Besides, he led testing and commissioning teams to implement electrical infrastructure projects for many types of industrial clients (Steel, Petrochemical, etc.) in both countries, Pakistan and Saudi Arabia.

Kashif possesses strong Project Management and technical skills in substation, automation system, design, testing, and commissioning of power generation, high voltage GIS/AIS Switchgear, Protection Relays, Protection, and Control Schemes, Automation System, etc.

As a protection and control, testing, and commissioning engineer, he participated and conducted much technical training internationally.

– Work Experience –

MAK Power – Director of Engineering (Apr 2024 – Present), Pakistan, UK

  • Fiddlers Ferry 275kV BESS: Complete Electrical Design including System Studies – 150MW Output.
  • Ferry Bridge 132kV BESS: Complete Electrical Design including System Studies – 150MW Output.
  • Doverdale Solar Farm – 132kV Substation: Complete Civil and Electrical Design including System Studies – 49.9MW Output.
  • Langford Solar Farm – 132kV Substation: Complete Civil and Electrical Design including System Studies – 50MW Output.
  • Basildon BESS: Civil and Electrical Design including System Studies – 28MW Output.
  • Cuxton – 132kV Substation: Electrical Design including System Studies.
  • Loudwater BESS: Civil and Electrical Design including System Studies – 40MW Output.
  • Ashorne Solar Farm: Grid System Studies including P28/P29, G5/4 G5/5 and G99 Studies.
  • Wolverhampton 33kV BESS: Power System Studies including P28/P29, G5/4 G5/5, G99 and Earthing Design.
  • Velmore 132kV Sub Station: Reinforcement and upgradation of existing 132kV Substation.
  • Halesworth BESS: Lightening Protection and Insulation Coordination Study.
  • Halesworth BESS: Protection and PSL Files for Relay Systems in the Protection Panel including 33kV incomer Panels and outgoing circuits.

K-Electric – Deputy General Manager Network Design & Protection (2022 – 2024), Karāchi, Sindh, Pakistan

  • Design review for protection and control panels
  • Preparation of Relay Specifications
  • HT & LT Network Design
  • Vendor Development
  • Relay Coordination
  • Short Circuit & Load Flow Studies
  • Leading DNO to DSO Transition
  • Power Quality ( Monitoring & Improvement)
  • Earthing Design
  • Preparation of SoP’s
  • Preparation of Technical Evaluation Reports
  • Performed HAZOP studies for KE network
  • Quality Champion for Network Engineering
  • Departmental Quality Champion at P&E
  • Trainer, performed protection-related training at KE DNA* Implemented the inrush blocking scheme at feeders
  • Implemented Broken conductor scheme at feeders
  • Introduce the concept of CT sizing calculation at KE
  • Assisted in the development of MV Network Design
  • Performed Relay , Fuse & MCCB coordination studies

ETCS – Manager T&C (2018 – 2022), Karachi, Pakistan

Given the Challenge of developing and running a new design & commissioning consultancy company in Pakistan.

  • Independent Engineer at 1263 Punjab Thermal Power Plant Jhang
  • 660kV HVDC Converter Station worked as Independent Engineer, CESI Hired Engineer
  • Testing & Commissioning of 132kV GETZ Pharma Substation & Extension of 132kV Line bay at KTGT
  • Operation & Maintenance of 132kV GETZ Pharma Substation
  • Extension of 132kV DHA-1 & Creek City Substation
  • End of Warranty Inspection of 132kV Hawa and 132kV JPL Wind Power Substations
  • Technical Support for investigating fault event and its rectification at 132kV Hawa Substation.
  • Consultation & Site Supervision of 132kV 50MW Gharo Solar Substation.
  • Consultation & Site Supervision of 132kV Navina Steel Substation.
  • Consultation & Site Supervision of 132kV Amreli Steel Substation.
  • Testing & Commissioning of 132kV Dhabeji-Amreli Steel Line.
  • Performed the annual testing of FCCL Fauji Cement Plant. Jhang Bahtar. Comprising of two 132/11kV transformer and switchgers.

Siemens (7 years)

Manager Technical (2 yrs) – Siemens First 380kV Project in SEC WOA, Jeddah, Saudi Arabia

Worked on the 380/110/11kV Substation Jeddah Central turnkey project of Saudi Electricity Company in Western Region (Worth 419 million SR ).Worked on the 380/110/11kV Substation

Senior Project Engineer Technical (2 yrs) – Project worth was 419 million SR, I was responsible for technical & project management support to PM. My involvement in the project was right from the start, and we followed all steps described below.

  • Provide technical support and supervise works by engineering aides and coordinate with external & internal consortium partners.
  • Ensure proper execution of testing & commissioning jobs by sub-contractors for upgrades and new projects.
  • Test & commission substation equipment of energized/existing substations, protection relays and auto & power transformers.
  • Manage contract administration, schedule coordination, quality control including supervision of tests and field decisions for utility construction projects achieving targeted results.
  • Advise other departments on all engineering matters
  • Prepare, review & edit project-related reports.
  • Study documents/drawings for new & upgrade projects and provide required technical comments.

Project Site Coordinator (1 yr) – 380/115/13.8kV Substation SS10J Yanbu

  • Plan overall schedule of testing and commissioning activities in coordination with project management team & submit to client/consultant for further approval to achieve the target.
  • Plan, implement & supervise the weekly schedule of testing & commissioning activities as per Overall all schedules.
  • Support, supervise & guide the Testing & Commissioning Engineers.
  • Attend weekly progress meetings with client/consultants/ project management and sub-contractor regarding technical and management issues.
  • Supervise installation & Erection work readiness to start commissioning activities.
  • Supervise cable termination work and modify termination work if required.
  • Review/Revise schedules, IFC drawings, Protection Schemes, Interlocks, test formats of main & auxiliary relays, Stability/Sensitivity of Bus Bar, TEE protection, Transformers & Reactors and modify (if required) as per client requirements, standard & Specification.
  • Command on fault analysis & troubleshooting to overcome the Substation Problems before & after Energization.
  • Perform Panel DC functional tests, Stability / Sensitivity of Bus Bar, TEE Protection and Transformers of 380/132/13.8KV, Scheme & Interlock check (if required) to achieve the targeted date of Energization.
  • Review and solve the deficiencies raised by the client during commissioning activities.
  • Follow-up with Client Punch Point to Clear ASAP so Project should complete without punch points.∙

Senior Substation Protection & Automation Engineer (1 yr 5 mos) – Saudi Aramco, 115kV Khursania Gas field

  • Completed extension of two 115kV line bays
  • Commissioned SEL relays, control & protection Scheme Test, GIS equipment test
  • LCC interlocking & scheme test, HI busbar stability & scheme test
  • SAS testing

National Transmission & Dispatch Company (NTDC), Pakistan (5 yrs 6 mos)

Protection & Instrument Engineer

  • Maintenance & Troubleshooting of faults in control circuits & protection scheme at AIS & GIS 500/220KV Grid Stations ( Jamshoro & NKI) and implement remedial measures.
  • Performed annual Protection Relay testing, Scheme testing, Battery maintenance, control scheme testing, trip test
  • Testing of GIS & AIS equipment,
  • Commissioned & tested two 220kV line bays, 450MVA transformer & supervised testing & commissioning of 500kV GIS grid NKI NTDC WAPDA

– Education & Achievements –

Mehran University of Engineering and Technology – B.E Electrical, Power B.E Electrical, Power 1999 – 2002

Technical Articles at EEP

– Strongest Skills –

Project Management
Substation Automation
Risk Management
Electrical Engineering
Testing
Power Transformer