An impedance Z comprising a resistance R in series with a reactance X can be converted to an admittance Y comprising a conductance G in parallel with a susceptance B:

Y = Z -1 = 1 / (R + jX) = (R – jX) / (R2 + X2) = R / (R2 + X2) – jX / (R2 + X2) = G – jB
G = R / (R2 + X2) = R / |Z|2
B = X / (R2 + X2) = X / |Z|2

Using the polar form of impedance Z:

Y = 1 / |Z|Ðf = |Z| -1Ð-f = |Y|Ð-f = |Y|cosf – j|Y|sinf

Conversely, an admittance Y comprising a conductance G in parallel with a susceptance B can be converted to an impedance Z comprising a resistance R in series with a reactance X:

Z = Y -1 = 1 / (G – jB) = (G + jB) / (G2 + B2) = G / (G2 + B2) + jB / (G2 + B2) = R + jX
R = G / (G2 + B2) = G / |Y|2
X = B / (G2 + B2) = B / |Y|2

Using the polar form of admittance Y:

Z = 1 / |Y|Ð-f = |Y| -1Ðf = |Z|Ðf = |Z|cosf + j|Z|sinf

The total impedance ZS of impedances Z1, Z2, Z3,… connected in series is:

ZS = Z1 + Z1 + Z1 +…

The total admittance YP of admittances Y1, Y2, Y3,… connected in parallel is:

YP = Y1 + Y1 + Y1 +…

In summary:
– use impedances when operating on series circuits,
– use admittances when operating on parallel circuits.

NOTATION
The symbol font is used for some notation and formulae. If the Greek symbols for alpha beta delta do not appear here [ a b d ] the symbol font needs to be installed for correct display of notation and formulae.
B
C
E
f
G
h
I
j
L
P
Q
susceptance
capacitance
voltage source
frequency
conductance
h-operator
current
j-operator
inductance
active power
reactive power
[siemens, S]
[farads, F]
[volts, V]
[hertz, Hz]
[siemens, S]
[1Ð120°]
[amps, A]
[1Ð90°]
[henrys, H]
[watts, W]
[VAreactive, VArs]
Q
R
S
t
V
W
X
Y
Z
f
w
quality factor
resistance
apparent power
time
voltage drop
energy
reactance
admittance
impedance
phase angle
angular frequency
[number]
[ohms, W]
[volt-amps, VA]
[seconds, s]
[volts, V]
[joules, J]
[ohms, W]
[siemens, S]
[ohms, W]
[degrees, °]
[rad/sec]

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

One Comment


  1. Ihsan
    Mar 30, 2020

    I am interested of load flow , Distributed Generation , security systems, contingency ranking,power flow performance index(PI) and voltage stability index(Lmn).Also programming load flow and indices.

Leave a Reply to Ihsan

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

seven  ×    =  21

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).