Partial Discharge Testing On Power Cable Systems
Partial discharge measurement is an important method of assessing the quality of the insulation of power cable systems, particularly for extruded insulation materials. This article considers partial discharge from two points of view: the measurement of all partial discharges occurring… Read more
Nov 18, 2011 | By Edvard Csanyi
Aluminium or copper busbar trunking? Myth busted!
Following years of copper being the material of choice for high power busbar trunking in the UK, yet aluminium reigning supreme in the rest of the world, Schneider Electric takes a look at the case for aluminium over copper busbar… Read more
Oct 19, 2011 | By Edvard Csanyi
How to locate underground faults on cable?
A common approach to test cable and determine insulation integrity is to use a Hi-pot test. In a hi-pot test, a DC voltage is applied for 5 to 15 min. IEEE-400 specifies that the hi-pot voltage for a 15-kV class… Read more
Oct 04, 2011 | By Edvard Csanyi
General considerations when choosing power cable
Thousands of cable types are used throughout the world. They are found in applications ranging from fibre-optic links for data and telecommunication purposes through to EHV underground power transmission at 275 kV or higher. Certain design principles are common to… Read more
May 04, 2011 | By Edvard Csanyi
Polyvinyl chloride (PVC) as jacketing material
PVC is the most widely used nonmetallic jacketing material in the wire and cable industry. Starting in 1935, when it first became available, the use of PVC grew rapidly because of its low cost, its easy processing, and its excellent… Read more
Apr 04, 2011 | By Edvard Csanyi
Electrical Wire – How It’s Made
Wikipedia: Electrical wiring in general refers to insulated conductors used to carry electricity, and associated devices. This article describes general aspects of electrical wiring as used to provide power in buildings and structures, commonly referred to as building wiring. Cant… Read more
Feb 03, 2011 | By Edvard Csanyi
The Switchboard Design Requirements
The following rules of design have to be implement in the aim to facilitate the assembly and especially the maintenance of the installation. The switchboard must be designed the way to have a clearly visible separation between the 3 following… Read more
Feb 01, 2011 | By Edvard Csanyi
Ethernet History
Ethernet is the most popular and widely deployed network technology in the world. In 1973, while working on a way to link the Xerox “Alto” computer to a printer, Bob Metcalfe designed and tested the first Ethernet network. This first… Read more
Jan 25, 2011 | By Edvard Csanyi
Comparison Of Cable Insulating Materials
Electrical insulation materials are employed over the metallic conductors of underground cables at all voltage ratings. Polymeric materials are employed as the insulation, but the nature of the polymer may vary with the voltage class. Since paper insulation was used… Read more
Jan 03, 2011 | By Edvard Csanyi
Megger Tests
The insulation resistance meter test method for determining the condition of electrical insulation has been widely used for many years as a general nondestructive test method. A serious limitation of this test is that its operating voltage of 500 to… Read more
Nov 26, 2010 | By Edvard Csanyi