Search

Premium Membership ♕

Join EEP PREMIUM today to unlock professional articles, specialized guides, and 50% discount on academy courses (lifetime access included)

Technical Articles Tagged With 'cables'

Cables

Cable spacing as a means of noise mitigation

In situations where there are a large number of cables varying in voltage and current levels, the IEEE 518-1982 standard has developed a useful set of tables indicating separation distances for the various classes of cables. There are four classification… Read more

Jul 11, 2014 | By

Cable spacing as a means of noise mitigation
Cables

Underfloor cable systems explained in details

It should be understood that the generic term ‘underfloor’ applies to products designed for such use but which may well be used in other environments where the protection is appropriate. Ducts and risers, and within suspended ceilings are typical spaces… Read more

Mar 24, 2014 | By

Underfloor cable systems explained in details
Cables

Underground residential distribution layouts

Where general appearance, economics, congestion, or maintenance conditions make overhead construction inadvisable, underground construction is specified. While overhead lines have been ordinarily considered to be less expensive and easier to maintain, developments in underground cables and construction practices have narrowed… Read more

Jan 18, 2013 | By

Underground residential distribution layouts
Cables

Testing and Commissioning of MV/HV Cables

Compare cable data with drawings and specifications. Inspect exposed sections of cables for physical damage. Inspect bolted electrical connections for high resistance using one or more of the following methods: Use of a low-resistance ohmmeter in accordance with Section 1.2 above…. Read more

Jan 12, 2013 | By

Testing and Commissioning of MV/HV Cables
Energy and Power

High resistance grounding equipment in mining applications

High resistance grounding equipment or permanently installed electrical distribution systems used in mines should be selected and applied as recommended for process industries. When mobile equipment is connected to the distribution system the grounding equipment and the ground fault protection should be designed… Read more

Aug 22, 2012 | By

High resistance grounding equipment in mining applications
Cables

Types of Cable Installations in Electrical Network

There are a variety of ways to install power distribution cables. Each method ensures distribution of power with a unique degree of reliability, safety, economy, and quality for any specific set of conditions. These conditions include the electrical characteristics of… Read more

Jul 27, 2012 | By

Types of cable installations in electrical network
Cables

Copper or aluminium? Which one to use and when?

Apart from their electrical conductivity, the other technologically important properties of copper and aluminium differ so significantly (density is an obvious example) that their areas of application are and have always been clearly distinct. And not a lot has changed… Read more

Mar 16, 2012 | By

System with two copper bus bars
Cables

Discussing About LV And HV Electrical Cables

Space is really a critical criterion when discussing electrical cables and wires. In a low-voltage (LV) plastic-sheathed cable with conductor cross-sections of up to 10 mm2 per conductor or in high-voltage (HV) cables (Figure 2), the lion’s share of the… Read more

Feb 08, 2012 | By

High-voltage cable cross section


Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.