Cable spacing as a means of noise mitigation
In situations where there are a large number of cables varying in voltage and current levels, the IEEE 518-1982 standard has developed a useful set of tables indicating separation distances for the various classes of cables. There are four classification… Read more
Jul 11, 2014 | By Edvard Csanyi
Underfloor cable systems explained in details
It should be understood that the generic term ‘underfloor’ applies to products designed for such use but which may well be used in other environments where the protection is appropriate. Ducts and risers, and within suspended ceilings are typical spaces… Read more
Mar 24, 2014 | By Edvard Csanyi
Eight important checks to do before powering up the dry-type transformer
The transformer should be powered up only after checking the following items: name plate ratings, parallel operation, connections: cables, busbars, tap change connections, grounding connection, thermal protective device, impurities removal and insulation resistance test. Make sure the name plate ratings… Read more
Oct 23, 2013 | By Edvard Csanyi
High voltage testing – Direct current (DC)
DC tests are used mainly to do “pressure tests” on high voltage cables. Although the cables operate with AC, AC testing is not practical. The high capacitance of the cables necessitates AC test sets with a high kVA rating to… Read more
Jun 01, 2013 | By Edvard Csanyi
Underground residential distribution layouts
Where general appearance, economics, congestion, or maintenance conditions make overhead construction inadvisable, underground construction is specified. While overhead lines have been ordinarily considered to be less expensive and easier to maintain, developments in underground cables and construction practices have narrowed… Read more
Jan 18, 2013 | By Edvard Csanyi
Testing and Commissioning of MV/HV Cables
Compare cable data with drawings and specifications. Inspect exposed sections of cables for physical damage. Inspect bolted electrical connections for high resistance using one or more of the following methods: Use of a low-resistance ohmmeter in accordance with Section 1.2 above…. Read more
Jan 12, 2013 | By Edvard Csanyi
Cable engineering in substations and power plants
Is it true that single core cable should be unarmored because eddy currents are induced in armor of single core cable which will cause additional losses? If true then why not three core cables also unarmored and why single core… Read more
Oct 22, 2012 | By Asif Eqbal
High resistance grounding equipment in mining applications
High resistance grounding equipment or permanently installed electrical distribution systems used in mines should be selected and applied as recommended for process industries. When mobile equipment is connected to the distribution system the grounding equipment and the ground fault protection should be designed… Read more
Aug 22, 2012 | By Edvard Csanyi
Guidelines to Visual inspection of Electrical Installations
In general terms we are inspecting the installation with regard to personal safety, equpment age, deterioration, equipment corrosion and overload. Suitability and external influence to the power system should also be included. At this point it is a good idea to… Read more
Jul 28, 2012 | By Edvard Csanyi
Types of Cable Installations in Electrical Network
There are a variety of ways to install power distribution cables. Each method ensures distribution of power with a unique degree of reliability, safety, economy, and quality for any specific set of conditions. These conditions include the electrical characteristics of… Read more
Jul 27, 2012 | By Edvard Csanyi
Sizing of power cables for circuit breaker controlled feeders (part 3)
Continued from article Sizing of power cables for circuit breaker controlled feeders (part 2) This criterion is applied so that the cross sectional area of the cable is sufficient to keep the voltage drop (due to impedance of cable conductor)… Read more
May 17, 2012 | By Asif Eqbal
Sizing of power cables for circuit breaker controlled feeders (part 2)
Continued from article Sizing of power cables for circuit breaker controlled feeders (part 1) This criterion is applied so that cross section of the cable can carry the required load current continuously at the designed ambient temperature and laying condition. Ampacity… Read more
May 13, 2012 | By Asif Eqbal
Sizing of power cables for circuit breaker controlled feeders (part 1)
The following three criteria apply for the sizing of cables for circuit breaker controlled feeders: [fancy_header]I. Short circuit current withstand capacity[/fancy_header] This criteria is applied to determine the minimum cross section area of the cable, so that cable can withstand… Read more
May 10, 2012 | By Asif Eqbal
Copper or aluminium? Which one to use and when?
Apart from their electrical conductivity, the other technologically important properties of copper and aluminium differ so significantly (density is an obvious example) that their areas of application are and have always been clearly distinct. And not a lot has changed… Read more
Mar 16, 2012 | By Edvard Csanyi
Discussing About LV And HV Electrical Cables
Space is really a critical criterion when discussing electrical cables and wires. In a low-voltage (LV) plastic-sheathed cable with conductor cross-sections of up to 10 mm2 per conductor or in high-voltage (HV) cables (Figure 2), the lion’s share of the… Read more
Feb 08, 2012 | By Edvard Csanyi