Technical Articles Tagged With 'circuit breaker'

Energy and Power

How circuit breaker trip unit works?

In addition to providing a means to open and close its contacts manually, a circuit breaker must automatically open its contacts when an overcurrent condition is sensed. The trip unit is the part of the circuit breaker that determines when… Read more

Mar 10, 2011 | By

How circuit breaker trip unit works?
Energy and Power

Ecodial 3 – FAQ’s

Remark : You may renumber the functional names with the Automatic numbering of the View menu. Version 3.2 of Ecodial works from a cable database. If such a cable exists in the database, then you can use it. The short… Read more

Jan 22, 2011 | By

Ecodial 3 - FAQ's
High Voltage

SF6 gas as insulating and arc-quenching medium

Sulphur hexafluoride gas (SF6) is employed as insulation in all parts of the installation, and in the circuit-breaker also for arc-quenching. SF6 is an electronegative gas, its dielectric strength at atmospheric pressure is approximately three times that of air. It… Read more

Jan 06, 2011 | By

Maintenance

Maintenance Of SF6 Gas Circuit Breakers

Sulfur Hexafluoride (SF6) is an excellent gaseous dielectric for high voltage power applications. It has been used extensively in high voltage circuit breakers and other switchgears employed by the power industry. Applications for SF6 include gas insulated transmission lines and’gas… Read more

Jan 04, 2011 | By

Maintenance Of SF6 Gas Circuit Breakers
Low Voltage

Maintenance Of Low Voltage Circuit Breakers

The deterioration of low voltage circuit breaker is normal and  this process begins as soon as the circuit breaker is installed. If  deterioration is not checked, it can cause failures and malfunctions. The purpose of an electrical preventive maintenance and… Read more

Dec 31, 2010 | By

Maintenance Of Low Voltage Circuit Breakers
Medium Voltage

Comparison Between Vacuum and SF6 Circuit Breaker

Until recently oil circuit breakers were used in large numbers for Medium voltage Distribution system in many medium voltage switchgears. There are number of disadvantages of using oil as quenching media in circuit breakers. Flammability and high maintenance cost are… Read more

Sep 05, 2010 | By

Comparison Between Vacuum and SF6 Circuit Breaker