Technical Articles Tagged With 'maintenance'

Energy and Power

Substation Switching Schemes

This technical article is intended to provide description and comparison of single line options for a DESN substation. The goal is to provide an analytical comparison for all options so that one can select the optimum solution considering cost, reliability,… Read more

Jun 26, 2012 | By

Switching Scheme Of Substation
Energy and Power

Inspection of electrical installations in home (1)

Europe has an ageing housing stock. There are many homes with outdated wiring. This wiring is deteriorating, has been inappropriately amended, or is insufficient for the electrical loads of today’s typical household. Many of the homes have not undergone any… Read more

Mar 24, 2012 | By

Electrical installations in home
Maintenance

Purpose and maintenance of transformer bushings

The two most common types of bushings used on transformers as main lead entrances are solid porcelain bushings on smaller transformers and oil-filled condenser bushings on larger transformers. Solid porcelain bushings consist of high-grade porcelain cylinders that conductors pass through…. Read more

Feb 05, 2012 | By

Transformer porcelain bushings spare parts
Maintenance

Maintenance Of Meduim Voltage Circuit Breakers

Medium-voltage circuit breakers rated between 1 and 72 kV may be assembled into metal-enclosed switchgear line ups for indoor use, or may be individual components installed outdoors in a substation. Air-break circuit breakers replaced oil-filled units for indoor applications, but… Read more

Apr 17, 2011 | By

Maintenance Of Meduim Voltage Circuit Breakers
Power Substation

Risk and Consequences Of Transformer Fire

The risk of a catastrophic fire with a properly inspected, tested, and maintained transformer is small. Proper maintenance and thorough testing of the transformer will prevent or detect many events that could lead to explosion and/or fire. However, unforeseen events… Read more

Feb 07, 2011 | By

Risk and Consequences Of Transformer Fire
Low Voltage

The Switchboard Design Requirements

The following rules of design have to be implement in the aim to facilitate the assembly and especially the maintenance of the installation. The switchboard must be designed the way to have a clearly visible separation between the 3 following… Read more

Feb 01, 2011 | By

Low voltage switchboard - Design requirements
Maintenance

Maintenance Of SF6 Gas Circuit Breakers

Sulfur Hexafluoride (SF6) is an excellent gaseous dielectric for high voltage power applications. It has been used extensively in high voltage circuit breakers and other switchgears employed by the power industry. Applications for SF6 include gas insulated transmission lines and’gas… Read more

Jan 04, 2011 | By

Maintenance Of SF6 Gas Circuit Breakers
Low Voltage

Maintenance Of Molded Case Circuit Breakers (MCCB)

The maintenance of circuit breakers deserves special consideration because of their importance for routine switching and for protection of other equipment. Electric transmission system breakups and equip­ment destruction can occur if a circuit breaker fails to operate because of a… Read more

Jan 01, 2011 | By

Molded Case Circuit Breakers (MCCB)
Low Voltage

Maintenance Of Low Voltage Circuit Breakers

The deterioration of low voltage circuit breaker is normal and  this process begins as soon as the circuit breaker is installed. If  deterioration is not checked, it can cause failures and malfunctions. The purpose of an electrical preventive maintenance and… Read more

Dec 31, 2010 | By

Maintenance Of Low Voltage Circuit Breakers
Maintenance

Maintenance for UPS systems

Maintenance of the UPS consists of preventive and corrective maintenance. Preventive maintenance consists of a scheduled list of activities. Performing these activities keeps the UPS in good working order and helps to prevent failures. Corrective maintenance is performed as a… Read more

Dec 16, 2010 | By

Maintenance for UPS systems
Energy and Power

Battery monitoring and maintenance guidelines

Battery monitoring has become a very popular topic, and many companies have either purchased equipment or are in the process of evaluating these systems. This article discusses why monitoring is important, and what parameters must be monitored. A brief explanation… Read more

Nov 21, 2010 | By

Battery Monitoring And Maintenance