Search

Premium Membership ♕

Join EEP PREMIUM today to unlock professional articles, specialized guides, and 50% discount on academy courses (lifetime access included)

Technical Articles Tagged With 'motor'

Electric Motor

Motor protection depending on size and voltage level

Motor protections vary widely depending on the size of the motor and voltage level involved, thus only the more common ones are discussed in this technical article. Index Motor Instantaneous Over-current Protection Motor Timed Over-Current Protection Thermal OverLoad Motor Ground… Read more

Aug 30, 2012 | By

Motor protection depending on size and voltage level
Electric Motor

Basics of 3-phase Induction Motor (part 4)

When a motor is expected to operate in unfavorable conditions such as: Intermittent overloading Higher ambient temperatures A restricted temperature rise as for a spinning mill, A refinery or a hazardous area Frequent starts, stops and reverses or any such… Read more

Aug 07, 2012 | By

1903 1/2hp Wagner repulsion start induction motor
Electric Motor

Basics of 3-phase Induction Motor (part 3)

Continued fro second part – Basics of 3-phase Induction Motor (part 2) Technical data to be specified by purchaser before purchasing a 3 phase induction motor: No. Technical data to be specified Data 1. General data about ambient temperature and… Read more

Aug 03, 2012 | By

Induction motor nameplate
Electric Motor

Basics of 3-phase Induction Motor (part 2)

Continued from first part – Basics of 3-phase Induction Motor (part 1) For the purpose of standardization, the preferred rated voltages of three phase induction motor shall be in accordance with IS 12360: 1988. The voltages for three phases, 50… Read more

Aug 02, 2012 | By

Basics of 3-phase Induction Motor (part 2)
Electric Motor

Basics of 3-phase Induction Motor (part 1)

This article will deal with those concepts of 3 phase induction motor which are essential prerequisite for proper selection, procurement, installation and maintenance of the same. Before any actual discussion on motor is started It will better to have a… Read more

Aug 01, 2012 | By

Basics of 3-phase Induction Motor (part 1)
Low Voltage

Assemblies of switchgear and control panels

Switchgear and control panels are found in power generating stations, transformer stations, distribution substations, commercial and institutional buildings, industrial plants and factories, refineries, paper mills, metal smelters and any other place where electric energy is utilized or electric power is… Read more

Jun 28, 2012 | By

Assemblies of switchgear and control panels
Electrical Lectures

DC Motor Drive Explained In Few Words

In a DC motor, the magnetic field is created by the current through the field winding in the stator. This field is always at right angles to the field created by the armature winding. This condition, known as field orientation,… Read more

Jun 23, 2012 | By

Figure 1 - Control loop of a DC Motor Drive
Electric Motor

Soft Starter In Industrial Applications

An induction motor connected directly to the power supply draws a constant magnetizing current at full speed, no matter what the load is. At anything less than full load, power factor of the induction motor is less than its rated… Read more

Jun 16, 2012 | By

Danfoss VLT® Soft Starter
Electric Motor

Advantages of Variable Speed Motors

Most motors are designed to operate at a constant speed and provide a constant output. While in many cases this may be more than adequate, it is not in all. Two-speed induction motors can improve efficiency for refrigerators, air conditioners,… Read more

Jun 13, 2012 | By

Danfoss AKD Variable Speed Drives
Electric Motor

Measurement of insulation resistance (IR) – Part 2

This article goes into details of insulation resistance values measured by Megger tester on many different kinds of equipment, such as switchgear, electrical wires & cables, electric motors, transmission & distribution lines, and other power system equipment. An insulation tester… Read more

Apr 29, 2012 | By

Fluke insulation resistance tester up to 10kV
Electric Motor

Direct On Line (DOL) Motor Starter

Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting. We use a variety of starters in order to protect the windings from being damaged by the high current flow that is… Read more

Apr 22, 2012 | By

Direct On Line (DOL) Motor Starter
Electric Motor

Star-delta motor starter explained in details

Where is Star-Delta motor starter used? Well, the majority of induction motors are started directly on line (DOL), but when very big motors are started in this manner, the large starting current surges produce a disruption in the voltage on… Read more

Apr 10, 2012 | By

Star-delta motor starter explained in details
Cables

Copper or aluminium? Which one to use and when?

Apart from their electrical conductivity, the other technologically important properties of copper and aluminium differ so significantly (density is an obvious example) that their areas of application are and have always been clearly distinct. And not a lot has changed… Read more

Mar 16, 2012 | By

System with two copper bus bars


Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.