Essential fundamentals of harmonics distortion for future power quality experts
It’s quite easy to understand what is the harmonics distortion. If you take a look at the past, you must notice that power system was much cleaner and straightforward. Most loads were primarily linear in nature. Linear loads draw the… Read more
Dec 30, 2019 | By Edvard Csanyi
Where and why you should use thyristor switched reactive power compensation
Various aspects of reactive power compensation problems have already been mentioned in previous articles. However, because of consistency of this article, we will remind ourselves briefly on basic terms and principles related to this field. Reactive power is a sort…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Dec 12, 2019 | By Miodrag Kokotovic
Reactive power compensation in electrical plants with generators
Compensation of reactive power applied in buildings or small facilities operates in the first and second quadrants of the coordinate system. Increasingly, complex industrial plants, for example plants burning wood dust, are using generators driven by steam engines running parallel… Read more
Oct 30, 2019 | By Edvard Csanyi
Operating centralized automatic compensation systems when supplying linear loads
For energy-efficient operation of decentralized multiply-fed industrial networks, each load-centre substation must have its own centralized reactive-power compensation system for automatic PF correction. The automatic reactive-power compensation systems used for load-related control of the reactive power comprise a PF controller… Read more
Sep 16, 2019 | By Edvard Csanyi
Reactive power and power factor correction essentials to ALWAYS keep on mind
Why reactive power and power factor correction are so important? Well, for experienced engineers, this is not the question but the fact. For young students who meet this matter and terms for the first time, it’s important to explain the… Read more
Sep 02, 2019 | By Edvard Csanyi
10 most common locations of shunt capacitors installed in a power system
It’s quite simple, using shunt capacitor banks to supply the leading currents required by the load relieves the generator from supplying that part of the inductive current. Both distribution and transmission systems benefit due to the application of shunt capacitors… Read more
Aug 26, 2019 | By Edvard Csanyi
How not to select the wrong generator set (genset) for your application
Generator set is maybe the most expensive part you can find in a substation. Therefore, many factors must be considered when determining the proper size or electrical rating of an electrical power generator set. If wrong size or rate is…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Jul 31, 2019 | By Edvard Csanyi
Four important factors related to proper application of a LV circuit breaker
Consideration of all the factors related to proper application of a low-voltage circuit breaker goes beyond voltage, current, and interrupting rating. The performance of a specific type of circuit breaker may be influenced by nonelectrical factors related to the installation… Read more
Oct 15, 2018 | By Edvard Csanyi
Installing and setting into operation of automatically controlled compensation banks
During previous decades manufacturers of automatic compensation banks faced increasing competition worldwide. They were forced to produce as economically as possible. Now, new technologies have been developed compared with the past when capacitors were bigger and heavier. Minimizing capacitors enabled… Read more
Jul 23, 2018 | By Edvard Csanyi
Why Raise the Power Factor? The Basics Every Electrical Engineer Should Understand.
A low power factor causes poor system efficiency. The total apparent power must be supplied by the electric utility. With a low power factor, or a high-kilovar component, additional generating losses occur throughout the system. Figures 1 and 2 below… Read more
Jun 06, 2018 | By Edvard Csanyi
Step-by-step tutorial for building capacitor bank and reactive power compensation panel
Design of reactive power compensation panel is much different and not that simple like standard distribution panel. When dealing with such panels, there are dozen of parameters to specify and other things to take care of. This article is the… Read more
Feb 28, 2018 | By Edvard Csanyi
10 Common Questions You Can Expect In Electrical Engineering Examination Test
This examination will focus on testing the fundamentals of electrical engineering from low voltage to high voltage. Of course, you can use huge EEP’s resources for help in calculations and finding right answers. Ok, let’s start with questions. You can… Read more
Dec 26, 2017 | By Edvard Csanyi
How To Control Reactive Power In Larger Electrical Plants With Multiple Incomers
Most compensation banks are controlled stepwise. For this purpose it is essential to ‘know’ when it is allowed to (de)activate a capacitor step by the power factor relay (controller). The so-called C/k value is calculated by the step size C… Read more
Nov 15, 2017 | By Edvard Csanyi
Three Applications Of Capacitor Banks Used To Correct The Load Power Factor
Capacitors are used in industrial premises for two basic functions: the first, to correct the load power factor, usually to meet the supplying authority’s supply requirements and avoid tariff penalties if the required power factor is not met, and the… Read more
Oct 27, 2017 | By Edvard Csanyi
Improvement of Power Quality via Dynamic Reactive Power Compensation Systems
In many cases, industrial plants are characterized in particular by the use of highly dynamic drive technology. In addition to the undeniable advantages of these modern technologies, there is the disadvantage that the electrical networks are strained because of frequent… Read more
Oct 11, 2017 | By Edvard Csanyi