Connections and composition of LV/MV/HV capacitor banks
Compensation capacitors are installed in numerous locations in electrical installations. They are to be found in high voltage transmission and distribution systems, in transformer substations and also at various levels in low voltage installations. Capacitors therefore have to be made… Read more
Jan 27, 2020 | By Edvard Csanyi
How to avoid common mistakes during wiring and startup of power factor correction (PFC) cubicle
Power factor correction (PFC) and reactive power compensation (RPC) are often used as synonyms in practice. Although they are similar and mutually dependent terms, they don’t represent the same thing. RPC is a procedure for reducing total reactive power of…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Spring Gift! - 20% Off on Pro Membership Plan with coupon 110KVAC
Upgrade
Jan 16, 2020 | By Miodrag Kokotovic
Where and why you should use thyristor switched reactive power compensation
Various aspects of reactive power compensation problems have already been mentioned in previous articles. However, because of consistency of this article, we will remind ourselves briefly on basic terms and principles related to this field. Reactive power is a sort…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Spring Gift! - 20% Off on Pro Membership Plan with coupon 110KVAC
Upgrade
Dec 12, 2019 | By Miodrag Kokotovic
Reactive power compensation in electrical plants with generators
Compensation of reactive power applied in buildings or small facilities operates in the first and second quadrants of the coordinate system. Increasingly, complex industrial plants, for example plants burning wood dust, are using generators driven by steam engines running parallel… Read more
Oct 30, 2019 | By Edvard Csanyi
Operating centralized automatic compensation systems when supplying linear loads
For energy-efficient operation of decentralized multiply-fed industrial networks, each load-centre substation must have its own centralized reactive-power compensation system for automatic PF correction. The automatic reactive-power compensation systems used for load-related control of the reactive power comprise a PF controller… Read more
Sep 16, 2019 | By Edvard Csanyi
Reactive power and power factor correction essentials to ALWAYS keep on mind
Why reactive power and power factor correction are so important? Well, for experienced engineers, this is not the question but the fact. For young students who meet this matter and terms for the first time, it’s important to explain the… Read more
Sep 02, 2019 | By Edvard Csanyi
10 most common locations of shunt capacitors installed in a power system
It’s quite simple, using shunt capacitor banks to supply the leading currents required by the load relieves the generator from supplying that part of the inductive current. Both distribution and transmission systems benefit due to the application of shunt capacitors… Read more
Aug 26, 2019 | By Edvard Csanyi
How harmonic filters prevent distortions in networks with high harmonic levels
The subject of this technical article are harmonic filters and their design. Filtering measures are recommended and may be required for electrical systems with too high harmonic levels. Filter circuits can absorb more harmonic currents. This means that, like reactor-protected… Read more
Jul 03, 2019 | By Edvard Csanyi
The theory behind reactive energy compensation that every engineer should know
Reactive energy compensation is an essential process in improving energy efficiency. It reduces the power consumption and thus its cost, enables optimum use of installations by preventing them being oversized, and more generally it improves the quality of energy systems…. Read more
May 22, 2019 | By Edvard Csanyi
Practical approach in design and installation of detuned capacitor banks
During last two or three decades, the number of nonlinear electrical loads inside all types of buildings and facilities (residential, business, commercial and industrial) has been significantly increased. All that caused the need for new approaches for electrical installation and…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Spring Gift! - 20% Off on Pro Membership Plan with coupon 110KVAC
Upgrade
Mar 15, 2019 | By Miodrag Kokotovic
How to start with the design of electrical installation?
The power analysis must be always at the very top of your tasks in the design of an electrical installation. It will enable the source(s) to be sized according to the purpose of the installation, the intended use of the… Read more
Feb 11, 2019 | By Edvard Csanyi
How to determine compensation of reactive power of an electrical installation
Improving the power factor of an electrical installation (compensation of reactive power) has many economic and technical advantages, but it’s not always easy to do so. There are numerous approaches to do such job, so let’s try to with this…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Spring Gift! - 20% Off on Pro Membership Plan with coupon 110KVAC
Upgrade
Jan 11, 2019 | By Edvard Csanyi
Installing and setting into operation of automatically controlled compensation banks
During previous decades manufacturers of automatic compensation banks faced increasing competition worldwide. They were forced to produce as economically as possible. Now, new technologies have been developed compared with the past when capacitors were bigger and heavier. Minimizing capacitors enabled… Read more
Jul 23, 2018 | By Edvard Csanyi
The Essentials Of Low Voltage Installations, Loads and Loads Modelling
Electrical installations are power systems aimed at final low voltage electricity consumption in homes, offices, and small companies. In electrical installation, electricity is usually taken from the public distribution network. Recently the concept of electrical installation has slightly evolved, since the…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Spring Gift! - 20% Off on Pro Membership Plan with coupon 110KVAC
Upgrade
Apr 20, 2018 | By Edvard Csanyi
This Is Why HVDC Transmission System Beats HVAC In These Essential Applications
For the most part, electric power is transmitted worldwide by means of ac. However, there are certain applications where dc transmission offers distinct economic and/or performance advantages. These applications include long-distance overhead transmission, underwater or underground transmission, and asynchronous ties… Read more
Dec 21, 2017 | By Edvard Csanyi