Technical Articles Tagged With 'resistance'

Energy and Power

An Overview Of Grounding System (Grounded)

Continued from technical article: An Overview Of Grounding System (Ungrounded) Solidly grounded system Resistance grounded system Reason for resistance grounding System earthing at EHV level Let us assume that R phase (Phase-3 in figure-3) is shorted to ground than: If… Read more

Oct 14, 2013 | By

An Overview Of Grounded Grounding System
Energy and Power

Comparison Of Neutral Earthing Methods

Neutral earthing systems are very similar to circuit breakers in that they do nothing until something in the system goes wrong! There are several methods for system earthing which can be generally divided into three main categories: Insulated earthing, Solid… Read more

Sep 16, 2013 | By

Comparison Of Neutral Earthing Methods
Electrical Lectures

The Rheostat In Few Simple Words

A variable resistor can be made from a wirewound element, rather than a solid strip of material. This is called a rheostat. A rheostat can have either a rotary control or a sliding control. This depends on whether the nichrome… Read more

Mar 20, 2013 | By

Startup rheostat of VL10 3 kV DC electric locomotive
Energy and Power

An Overview Of Short Circuit Current (part 3)

Fault calculations are carried out to find the magnitude of fault current at various voltage levels of electrical system. One of the key components in the calculation process is to determine the total impedance of the circuit from the utility /… Read more

Mar 08, 2013 | By

An Overview Of Short Circuit Current (part 3)
Energy and Power

Inspection and Test Procedures for Metal-Enclosed Busways

Visual and Mechanical Inspection Electrical Tests Test Values Test Values – Visual and Mechanical Test Values – Electrical Tables: TABLE 100.12 – US Standard Fasteners Bolt-Torque Values for Electrical Connections TABLE 100.1 – Insulation Resistance Test Values Electrical Apparatus and… Read more

Dec 22, 2012 | By

Inspection and Test Procedures for Metal-Enclosed Busways
Energy and Power

Testing and Commissioning of Metal-Clad Switchgear

Electrical testing and commissioning of Metal-Clad switchgear is essential to the safe start for the first time, regardless of its size, type or industry. This article covers testing and start-up / commisioning procedures for all the components of medium voltage… Read more

Sep 24, 2012 | By

Distribution substation - 20/04kV MCset metal-clad switchgear (Schneider Electric)
Electrical Lectures

Water-and-Pipe Analogy for Ohm’s Law

Ohm’s Law also makes intuitive sense if you apply it to the water-and-pipe analogy. If we have a water pump that exerts pressure (voltage) to push water around a ”circuit” (current) through a restriction (resistance), we can model how the three… Read more

Aug 15, 2012 | By

An analogy for Ohm’s Law
Electric Motor

Measurement of insulation resistance (IR) – Part 2

This article goes into details of insulation resistance values measured by Megger tester on many different kinds of equipment, such as switchgear, electrical wires & cables, electric motors, transmission & distribution lines, and other power system equipment. An insulation tester… Read more

Apr 29, 2012 | By

Fluke insulation resistance tester up to 10kV


Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.