What is what in outdoor HV substation? How to identify elements by shape and function?
It’s not always an easy task to explain what is what in high voltage substations. Shapes of the major elements are mostly similar through substations, but there are also combinations of two and more elements with integrated functions. This technical… Read more
Jan 10, 2018 | By Edvard Csanyi
HV Transmission Line Components (Towers, Conductors, Substations, ROWs and Roads)
The towers and conductors of a transmission line are familiar elements in our landscape. However, on closer inspection, each transmission line has common components with unique characteristics, beginnings and ends. In this article, we list main transmission line components and… Read more
Jan 08, 2018 | By Edvard Csanyi
What does a good grounding of the power substation and switching station really mean?
Provision of adequate grounding in a substation and switching stations are very important for the safety of operating personnel as well a electrical devices do not rise above tolerable thresholds and that the earth connection is rugged to dissipate the… Read more
Dec 18, 2017 | By Edvard Csanyi
Troubleshooting Transformer In Power Substation And Detailed Failure Investigation
Failure of transformer in power substation is not a sudden phenomenon, for that matter each and every failure will take place only after alerting through some pre-signs. If they went unnoticed or unattended will result in failure. Therefore it is… Read more
Nov 06, 2017 | By Edvard Csanyi
The Structure of Electric Power Systems: Energy Generation, Distribution and Transmission
From a general perspective, an electric power system is usually understood as a very large network that links power plants (large or small) to loads, by means of an electric grid that may span a whole continent, such as Europe… Read more
Oct 09, 2017 | By Edvard Csanyi
Seven design diagrams that every HV substation engineer MUST understand
A substation engineer should have a good understanding of the electrical equipment and layout of HV power substation. It’s also important to understand relationship between protection and the other equipment in the substations and the distribution system. Beside this, it’s… Read more
Oct 04, 2017 | By Edvard Csanyi
Substation ownership demarcation between the utility and the plant (considerations & issues)
The substation ownership demarcation between the utility and the plant is very important and should be determined carefully. Specific ownership of the substation and associated equipment may be a complicated issue that may be determined by a number of conditions… Read more
Sep 18, 2017 | By Edvard Csanyi
How to specify real service conditions for LV/MV equipment inside a substation
The various service conditions for the MV equipment inside substation are linked to the design of the installation, the design of the operating room, the site and the application surrounding the installation, and finally, the seasons. The combination of these… Read more
Sep 13, 2017 | By Edvard Csanyi
The analysis of four network schemes in terms of reliability and protection
Before sizing an electric network, the single-line diagram of the electric network must be defined on the basis of: Load – it is considered fundamental to establish the true user and service requirements these are destined for, in terms of quality, availability… Read more
Mar 24, 2017 | By Edvard Csanyi
Four design criteria for human machine interface (HMI) in a substation
With the introduction of IEDs (Intelligent Electronic Devices), the traditional switchboard interface is being replaced by Human Machine Interface (HMI) software loaded on computer hardware. The designer has a wide choice of HMI vendors that support a wide range of… Read more
Jan 11, 2017 | By Edvard Csanyi
A case study of 110/10 kV substation with centralized protection, automation and control system
Centralized substation protection and control has been attempted in the past based on the available technology. This evolution is now at the intersection of sensing, protection and communication technologies, providing the unique opportunity to develop a more reliable and maintainable… Read more
Dec 21, 2016 | By Edvard Csanyi
High voltage station – Design, construction and commissioning process
The development of a high-voltage (HV) substation is a massive multidisciplinary undertaking. Recent trends in utilities have heavily favored sourcing the design and construction of HV stations through EPC (Engineering, Procurement, and Construction) or turnkey contracts. Regardless of the procurement… Read more
Nov 11, 2016 | By Edvard Csanyi
Problems with audible substation noise and what you can do about it
Audible substation noise, particularly continuously radiated discrete tones (e.g., from power transformers), is the type of noise that the community may find unacceptable. Community guidelines to ensure that acceptable substation noise levels are maintained can take the form of governmental… Read more
Oct 03, 2016 | By Edvard Csanyi
What happens when a transformer fire occurs in a substation
If a fire occurs as a result of a failure in a transformer, then the transformer is nearly always a total write off. However, the total cost of a transformer fire is typically in the order of 2-3 times the… Read more
Aug 12, 2016 | By Edvard Csanyi
Clearance Requirements In EHV AIS Substation You MUST Respect
Starting point for planning a substation is its single line diagram (SLD) which relates to circuit configuration, number of bus bars and its type and other associated equipment. However from erection and installation point of view layout of any substation… Read more
May 25, 2016 | By Asif Eqbal