Sizing of power cables for circuit breaker controlled feeders (part 2)
Continued from article Sizing of power cables for circuit breaker controlled feeders (part 1) This criterion is applied so that cross section of the cable can carry the required load current continuously at the designed ambient temperature and laying condition. Ampacity… Read more
May 13, 2012 | By Asif Eqbal
What is the best transformer coolant?
One of the main sources of losses and reasons for temperature rise in various parts of a transformer are the magnetic circuit and windings. So what are the actually reasons of heating the transformer? Responsible for heat generation within the… Read more
Apr 20, 2012 | By Edvard Csanyi
Fire Properties Of Cables
This is an area of increasing public and legislative concern, and therefore of increasing interest to engineers. There have been major advances in the fire performance of cables in recent years, and table below lists some of the relevant standards…. Read more
Nov 21, 2011 | By Edvard Csanyi
How heat pump works?
The heat pump transfers the heat between the heating/cooling distribution system and the earth connection. It is the basic building block of the GSHP system. The most common type of heat pump used with GSHP systems is a “water-to-air” unit… Read more
Jun 10, 2011 | By Edvard Csanyi
Colour classification and temperature
Colour is a subjective psycho physiologic interpretation of the visible electromagnetic spectrum. Luminous sensations or images, produced in our retina, are sent to the brain and interpreted as a set of monochromatic sensations which constitute the colour of the light…. Read more
Mar 22, 2011 | By Edvard Csanyi
How to choose transformer rating?
When an installation is to be supplied directly from a MV/LV transformer and the maximum apparent-power loading of the installation has been determined, a suitable rating for the transformer can be decided, taking into account the following considerations: The possibility… Read more
Mar 12, 2011 | By Edvard Csanyi
Transformer Winding Temperature Thermometer
These devices are supposed to indicate hottest spot in the winding based on the manufacturers heat run tests. At best, this device is only accurate at top nameplate rated load and then only if it is not out of calibration…. Read more
Feb 25, 2011 | By Edvard Csanyi
Danfoss – Max uptime for wind turbines
Located on top of towers that can extend 80 to 110 meters into the air, wind turbines are subjected to powerful operating forces. And because wind turbines are difficult to access for maintenance and repair, reliable monitoring and control components,… Read more
Nov 29, 2010 | By Edvard Csanyi