NEC Requirements for Emergency Systems
Emergency systems are generally installed in buildings that are or can be occupied by 1000 or more persons or are more than 75 ft high. These are buildings where artificial illumination is required for safe exiting and for panic control…. Read more
Oct 12, 2012 | By Edvard Csanyi
Switching Impulse Test of the Transformer
The switching impulse test is applied to confirm the withstand of the transformer’s insulation against excessive voltages occurring during switching. During the switching impulse voltage test, the insulation between windings and between winding and earth and withstand between different terminals… Read more
Oct 11, 2012 | By Edvard Csanyi
Safety Clearance Recommendations for Electrical Panel
Working Space around Indoor Panel/Circuit Board (NES 312.2) Clearance around an Indoor electrical panel (NEC 110.26) Clearance for Conductor Entering in Panel (NES 408.5) Clearance between Bare Metal Busbar in Panel (NES 408.5) Clearance of Outdoor electrical panel to Fence/Wall… Read more
Oct 10, 2012 | By Jignesh Parmar
Fire-Fighting Precautions in Power Substation
The layout of the plant and the design of the building play a major part in reducing the spread of fire and the effect of explosions. For example, equipment and buildings should be arranged to have vents which rupture rather… Read more
Oct 09, 2012 | By Edvard Csanyi
Overcurrent protection of transformer (NEC 450.3)
The overcurrent protection required for transformers is consider for Protection of Transformer only. Such overcurrent protection will not necessarily protect the primary or secondary conductors or equipment connected on the secondary side of the transformer. Introduction Overcurrent protection of transformers… Read more
Oct 08, 2012 | By Jignesh Parmar
Disturbances In LV Networks Due To Surges
There are two types of surge: those generated by a lightning impact and those resulting from electrical switchgear switching operations. Surges resulting from lightning strokes (see figure below) can affect all electrical installations. Consequently, they are without doubt the main… Read more
Oct 06, 2012 | By Edvard Csanyi
How to Protect Capacitor Banks?
Capacitor banks are used to compensate for reactive energy absorbed by electrical system loads, and sometimes to make up filters to reduce harmonic voltage. Their role is to improve the quality of the electrical system. They may be connected in… Read more
Oct 05, 2012 | By Edvard Csanyi
Basic steps in PLC programming for beginners
The first step in developing a control program is the definition of the control task. The control task specifies what needs to be done and is defined by those who are involved in the operation of the machine or process…. Read more
Oct 04, 2012 | By Edvard Csanyi
Dry Transformer Percent Impedance Definition
The percent impedance is the percent voltage required to circulate rated current flow through one transformer winding when another winding is short-circuited at the rated voltage tap at rated frequency. %Z is related to the short circuit capacity of the transformer during short… Read more
Oct 03, 2012 | By Edvard Csanyi
Definitions of Abnormal Voltage Conditions
A sag is a temporary reduction in the normal AC voltage. A momentary sag is a variation, which lasts for a period of 0.5 cycle to about 2 s usually the result of a short circuit somewhere in the power system. Instances… Read more
Oct 02, 2012 | By Edvard Csanyi
Designing of HV Power Substation and Layout
Introduction Earthing and Bonding Substation Earthing Calculation Methodology (Earthing Materials) Layout of Substation Different Layouts for Substations (single busbar, mesh, 1 1/2 cb) Principle of Substation Layouts (spatial separation, maintenance zones) Components of a Substation (cbs, cts, isolators, insulation, transformers etc.) Substations are the… Read more
Oct 01, 2012 | By sprabakar22
Right Choice of Dry Type or Liquid-Filled Transformer
1. Two Types of Transformers 2. Cooling and insulating system 3. Losses 4. Operating Life of Transformer 5. Maintainability 6. Repairability 7. Core/Coil Reclamation and Recycling 8. Operating Sound Level and Noise Pollution 9. Footprint 0. Conclusion Information on the… Read more
Sep 29, 2012 | By Edvard Csanyi
Overview of Single Phase Induction Type Energy Meter
Single phase induction type energy meter is also popularly known as watt-hour meter. This name is given to it. This article is only focused about its constructional features and its working. Induction type energy meter essentially consists of following components:… Read more
Sep 28, 2012 | By Bipul Raman
What is the difference between Bonding, Grounding and Earthing?
One of the most misunderstood and confused concept is difference between Bonding, Grounding and Earthing. Bonding is more clear word compare to Grounding and Earthing, but there is a micro difference between Grounding and Earthing. Earthing and Grounding are actually… Read more
Sep 27, 2012 | By Jignesh Parmar
How Sensitive Circuits Are Affected By Noise And What Can You Do About It?
Noise is only important if it is measured in relation to the communication signal, which carries the data or information. Electronic receiving circuits for digital communications have a broad voltage range, which determines whether a signal is binary bit ‘1’… Read more
Sep 26, 2012 | By Edvard Csanyi