Technical Articles

Electric Motor

Basics of 3-phase Induction Motor (part 3)

Continued fro second part – Basics of 3-phase Induction Motor (part 2) Technical data to be specified by purchaser before purchasing a 3 phase induction motor: No. Technical data to be specified Data 1. General data about ambient temperature and… Read more

Aug 03, 2012 | By

Induction motor nameplate
Electric Motor

Basics of 3-phase Induction Motor (part 2)

Continued from first part – Basics of 3-phase Induction Motor (part 1) For the purpose of standardization, the preferred rated voltages of three phase induction motor shall be in accordance with IS 12360: 1988. The voltages for three phases, 50… Read more

Aug 02, 2012 | By

Basics of 3-phase Induction Motor (part 2)
Electric Motor

Basics of 3-phase Induction Motor (part 1)

This article will deal with those concepts of 3 phase induction motor which are essential prerequisite for proper selection, procurement, installation and maintenance of the same. Before any actual discussion on motor is started It will better to have a… Read more

Aug 01, 2012 | By

Basics of 3-phase Induction Motor (part 1)
Cables

Sizing and protection of the neutral conductor (2)

Continued from the first part – Sizing and Protection of the Neutral Conductor (1) If the neutral conductor is correctly sized (including harmonics), no specific protection of the neutral conductor is required because it is protected by the phase protection. If… Read more

Jul 31, 2012 | By

Sizing and protection of the neutral conductor (2)
Cables

Sizing and protection of the neutral conductor (1)

Sizing (c.s.a.) and the protection of the neutral conductor, apart from its current-carrying requirement, depend on several factors, namely: The type of earthing system, TT, TN, etc. The harmonic currents The method of protection against indirect contact hazards according to… Read more

Jul 30, 2012 | By

Sizing and protection of the neutral conductor
Cables

Types of Cable Installations in Electrical Network

There are a variety of ways to install power distribution cables. Each method ensures distribution of power with a unique degree of reliability, safety, economy, and quality for any specific set of conditions. These conditions include the electrical characteristics of… Read more

Jul 27, 2012 | By

Types of cable installations in electrical network
Energy and Power

Overvoltages in the IT system

Electrical networks can be subject to overvoltages of varying origins. Some overvoltages, such as differential mode ones (between live conductors) affect all the earthing systems. This section is particularly concerned with common mode overvoltages, which mainly affect the IT system… Read more

Jul 26, 2012 | By

Single insulation fault on a network operated in IT earthed system
Energy and Power

Isolating the Fault With Time-based Discrimination

Protection functions form a consistent system depending on the overall structure of the power distribution system and the neutral earthing arrangement. They should therefore be viewed as a system based on the principle of discrimination, which consists of isolating the… Read more

Jul 22, 2012 | By

Isolating the Fault With Time-based Discrimination
Energy and Power

Bus Design In Aboveground Substations

Substations can be constructed partly or entirely within aboveground or belowground enclosures. However, cost is high and complexity is increased by fire-protection and heat-removal needs. The following discussion deals with exposed aboveground substations. The bus and associated substation equipment are… Read more

Jul 21, 2012 | By

Gas insulated switchgear (GIS) - Siemens
Energy and Power

Effect of Lightning Strike on Electrical Lines

The foregoing discussion concentrated on the principles of lightning strikes and how their effects can be mitigated. However, lightning strikes on electrical lines or substations are those that cause problems in the distribution network which come right into our residences… Read more

Jul 20, 2012 | By

Effect of lightning strike on electrical lines