Technical Articles

Industrial Automation

Using MODBUS for Process Control and Automation (1)

MODBUS is the most popular industrial protocol being used today, for good reasons. It is simple, inexpensive, universal and easy to use. Even though MODBUS has been around since the past century nearly 30 years, almost all major industrial instrumentation… Read more

May 21, 2012 | By

The Schneider Electric PLC - Modicon Quantum
Energy and Power

Special considerations when selecting transformer protection

Current transformer ratio selection and performance require special attention when applying transformer protection. Unique factors associated with transformers, including its winding ratios, magnetizing inrush current, and the presence of winding taps or load tap changers, are sources of difficulties in… Read more

May 19, 2012 | By

Dry-type power transformers 11/0.42kV 2000kVA
Electrical Lectures

Power Measurement In AC Circuits

Power measurement in AC circuits can be quite a bit more complex than with DC circuits for the simple reason that phase shift complicates the matter beyond multiplying voltage by current figures obtained with meters. What is needed is an instrument… Read more

May 15, 2012 | By

GE Watthour Meter
Energy and Power

Introduction to instrument transformers

Instrument transformers (ITs) are designed to transform voltage of current from the high values in the transmission and distribution systems to the low values that can be utilized by low voltage metering devices. There are three primary applications for which… Read more

May 14, 2012 | By

Instrument transformers - ABB
Metering

An Overview Of Clamp Meter

Clamp-on ammeter or simply ‘clamp meter’ is an instrument that is used to measure the current flowing through a conductor. An AC Clamp meter basically consists of a current transformer in its jaws, bar CT usually. Utilizing the principle of… Read more

May 06, 2012 | By

Clapm meter
Energy and Power

Using AC and DC together in electrical system?

There are a number of issues to using AC and DC together in the same electrical system. Briefly, they are: circuit boxes and hardware, outlets, wiring schemes and sizes, and switches. The Electrical Code prohibits AC and DC in the same box. You’ll need two… Read more

May 05, 2012 | By

Using AC and DC together in electrical system?
Energy and Power

Types of Residual Current Devices (RCD)

For domestic applications only the first five of the below listed residual current devices (RCD) need to be considered. For industrial and commercial buildings all of the classifications need to be considered. Table below aims to identify where each type… Read more

May 03, 2012 | By

Residual current device 30mA - SIEMENS
Energy and Power

Time relays setting ranges explained in details

Time relays are used in control switching operations involving time delay. Most of these time relays have multiple time setting ranges and most of them are explained below. Time relays perform either on-delay or off-delay timing. An arrow is used… Read more

Apr 30, 2012 | By

Siemens SIRIUS 3RP25 timing relay with microprocessor, OFF delay without auxiliary voltage, fully cover the functionality of the predecessor types on ASIC basis
Electric Motor

Measurement of insulation resistance (IR) – Part 2

This article goes into details of insulation resistance values measured by Megger tester on many different kinds of equipment, such as switchgear, electrical wires & cables, electric motors, transmission & distribution lines, and other power system equipment. An insulation tester… Read more

Apr 29, 2012 | By

Fluke insulation resistance tester up to 10kV
Cables

Measurement of insulation resistance (IR)

The measurement of insulation resistance is a common routine test performed on all types of electrical wires and cables. As a production test, this test is often used as a customer acceptance test, with minimum insulation resistance per unit length… Read more

Apr 28, 2012 | By

Megger MIT1020 10-kV insulation resistance testers are all designed specifically to assist the user with the testing and maintenance of high voltage equipment