Technical Articles

Energy and Power

Overview Of Electrical Loads In Building

The electrical design professional should determine a building’s electrical load characteristics early in the preliminary design stage of the building to select the proper power distribution system and equipment having adequate power capacity with proper voltage levels, and sufficient space… Read more

Apr 27, 2012 | By

Low voltage switchgear type 'OKKEN' - Schneider Electric
Lighting

Light Emission Depreciation

Illuminance provided initially by a lighting installation will decrease in a gradual way during its use due to a reduction in lamp lumens, to lamps which burn down, and to accumulation of dirtiness in lamps, luminaires and surfaces of the… Read more

Apr 24, 2012 | By

Dirty surface of the fluoroscent lamp
Electric Motor

Direct On Line (DOL) Motor Starter

Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting. We use a variety of starters in order to protect the windings from being damaged by the high current flow that is… Read more

Apr 22, 2012 | By

Direct On Line (DOL) Motor Starter
Transformers

What is the best transformer coolant?

One of the main sources of losses and reasons for temperature rise in various parts of a transformer are the magnetic circuit and windings. So what are the actually reasons of heating the transformer? Responsible for heat generation within the… Read more

Apr 20, 2012 | By

What is the best transformer coolant?
Metering

Analog Data Acquisition with Transducers

Transducers measure power system parameters by sampling instrument transformer secondaries. They provide a scaled, low-energy signal that represents a power system quantity that the SA interface controller can easily accept. Transducers also isolate and buffer the SA interface controller from… Read more

Apr 19, 2012 | By

Current transducer
Electrical Lectures

Inspection Of Voltage Drop In Conductors

It is part of the inspection process to ensure that installed conductors have been correctly selected for current carrying capacity and voltage drop. To check the suitability of the current carrying capacity it is simply a matter of looking at… Read more

Apr 15, 2012 | By

Inspection Of Voltage Drop In Conductors
Electrical Lectures

What is incident energy caused by arc flash?

Incident energy is the energy per unit area received on a surface located a working distance away from the arc flash location. The working distance is the distance from where the worker to the flash location. This is basically an… Read more

Apr 13, 2012 | By

Arc flash in switchboard
Energy and Power

Key Cyber Security Purposes for the Smart Grid

In the Smart Grid, there are two key purposes for cyber security: Keep electricity flowing to customers, businesses, and industry. For decades, the power system industry has been developing extensive and sophisticated systems and equipment to avoid or shorten power… Read more

Apr 12, 2012 | By

Key Cyber Security Purposes for the Smart Grid
Electric Motor

Star-delta motor starter explained in details

Where is Star-Delta motor starter used? Well, the majority of induction motors are started directly on line (DOL), but when very big motors are started in this manner, the large starting current surges produce a disruption in the voltage on… Read more

Apr 10, 2012 | By

Star-delta motor starter explained in details
Electrical Lectures

Short review of resistance, reactance and impedance

Resistance is essentially friction against the motion of electrons. It is present in all conductors to some extent (except superconductors!), most notably in resistors. When alternating current goes through a resistance, a voltage drop is produced that is in-phase with… Read more

Apr 08, 2012 | By

Figure 1 - Perfect resistor, inductor and capacitor
Medium Voltage

Erection Procedures For Medium Voltage Switchgear

Before commencing erection of medium voltage (MV) switchgear check that all connections are tight on busbars and on main and auxiliary circuits. Examine the insulation carefully, because there have been cases of burned out connections due to failure to observe… Read more

Apr 03, 2012 | By

Erection of ABB's Unigear medium voltage switchgear
Energy and Power

Single-Phase Power vs Three-Phase Power

The principal elements of an electric power system are the generating stations, the transmission lines, the substations, and the distribution networks. The generators produce the electricity, the transmission lines move it to regions where it is consumed, and the substations… Read more

Apr 01, 2012 | By

Single-Phase Power vs Three-Phase Power - Differences
Lighting

Architectural Luminaires – Unusual Visual Effects

Architectural luminaires are custom-designed and built fixtures that offer features not available in commercial luminaires. They can be built to fit specific locations or perform desired functions as well as provide unusual visual effects. These luminaires can be made from… Read more

Mar 31, 2012 | By

Architectural luminaires used for interior lighting design