The Physics of Light
Man has always been fascinated by light and has constantly striven to unravel its mysteries. History has produced various theories that today strike us as comical but were seriously propounded in their time. For example, since no connection could be… Read more
Dec 11, 2011 | By Edvard Csanyi
How a Geothermal Plant Works?
Understanding geothermal energy begins with an understanding of the source of this energy – the earth’s internal heat. The Earth’s temperature increases with depth, with the temperature at the center reaching more than 4200 °C (7600 °F). A portion of… Read more
Dec 10, 2011 | By Edvard Csanyi
Internal arc testing of MV switchgear – IEC 62271-200 (part one)
Medium voltage air-insulated and gas-insulated switchgear for electrical transmission and distribution are designed and tested in accordance to national and international standards to guarantee high reliability of operation and safety. Manufacturers of electrical switchgear develop, in a continuous dialog with… Read more
Dec 10, 2011 | By Edvard Csanyi
What is the resonance phenomena?
The use of both capacitive and inductive devices in distribution systems leads to resonance phenomena, resulting in extremely high or low impedance values. These variations in impedance modify the current and voltage in the distribution system. Here we will discuss… Read more
Dec 09, 2011 | By Edvard Csanyi
Why and how much for fire protection of power plant?
Fire protection measures can be subdivided into life-safety and investment categories. Life-safety measures are considered to be mandatory by fire codes, building codes, or safety codes. As such, the codes mandate specific types of substation fire protection, with very little… Read more
Dec 07, 2011 | By Edvard Csanyi
Flexible AC Transmission System – What and Why?
Flexible AC Transmission System (FACTS) have been evolving to a mature technology with high power rating. This technology has wide spread application, became a top rate, most reliable one, based on power electronics. The main purpose of these systems is… Read more
Dec 05, 2011 | By Edvard Csanyi
5 steps to choose the best motor for your application
For line-operated motors, loads fall into three general categories: constant torque, torque that changes abruptly, and torque that change gradually over time. Bulk material conveyors, extruders, positive displacement pumps, and compressors without air unloaders run at relatively steady levels of… Read more
Dec 03, 2011 | By Edvard Csanyi
Guideline to Design Electrical Network for Building (Small Area)
Find out built up area in Sqft.of per flat per House/Dwelling unit. Multiply area in Sqft. by Load/Sqft according to following table: Type of Load Load/Sqft Industrial 100 Watt/Sqft Commercial 30 Watt/Sqft Domestic 15 Watt/Sqft Apply the diversity factor and… Read more
Dec 02, 2011 | By Jignesh Parmar
Transient Voltage Surge Suppressors
Transient Voltage Surge Suppressor (TVSS) is a device that every data center or mission critical facility should have. Why should every data center have one and what does it do you ask? The purpose of a TVSS is to eliminate… Read more
Dec 01, 2011 | By Edvard Csanyi
Transformer and Transformer-Feeder Protection
The development of modern power systems has been reflected in the advances in transformer design. This has resulted in a wide range of transformers with sizes ranging from a few kVA to several hundred MVA being available for use in… Read more
Nov 30, 2011 | By Edvard Csanyi
Overvoltages Caused by Direct Lightning Strokes
A lightning stroke is defined as a direct stroke if it hits either the tower or the shield wire or the phase conductor. This is illustrated in Figure 1. When the insulator string at a tower flashes over by direct… Read more
Nov 29, 2011 | By Edvard Csanyi
What is the reason beyond three phase transmission?
As the need for increased transmission line capacity have forced power utility and owner to maximize power density in existing transmission corridors. Many experienced have already been done on this, one way to get to this goal (increased capacity), is… Read more
Nov 28, 2011 | By Edvard Csanyi
Power Semiconductor Device – MOSFET
Power MOSFETs are marketed by different manufacturers with differences in internal geometry and with different names such as MegaMOS, HEXFET, SIPMOS, and TMOS. They have unique features that make them potentially attractive for switching applications. They are essentially voltage-driven rather… Read more
Nov 27, 2011 | By Edvard Csanyi
Why do we need variable speed drives (VSD)?
There are many and diverse reasons for using variable speed drives. Some applications, such as paper making machines, cannot run without them while others, such as centrifugal pumps, can benefit from energy savings. In general, variable speed drives are used… Read more
Nov 25, 2011 | By Edvard Csanyi
A Look at the Power Rating of Resistors
You may be asked: “what is the power rating of the resistors you want to buy?” when buying a resistor to build a certain circuit. For the most standard class of resistors, you may simply be given ¼ Watt resistor…. Read more
Nov 24, 2011 | By elaina