Technical Articles

Basics Of Subtransmission Systems

Subtransmission systems are those circuits that supply distribution substations. Several different subtransmission systems can supply distribution substations. Common subtransmission voltages include 34.5, 69, 115, and 138 kV. Higher voltage subtransmission… Read more

Dec 17, 2010 | High Voltage

Transmission Lines

Maintenance for UPS systems

Maintenance of the UPS consists of preventive and corrective maintenance. Preventive maintenance consists of a scheduled list of activities. Performing these activities keeps the UPS in good working order and… Read more

Dec 16, 2010 | Maintenance

Maintenance for UPS systems

Solar Power Tower

Solar power towers generate electric power from sunlight by focusing concentrated solar radiation on a tower mounted heat exchanger (receiver). The system uses hundreds to thousands of sun-tracking mirrors called… Read more

Dec 15, 2010 | Solar Power

Keeping Motor Windings Dry

Special provision should be made to protect motor windings which operate in a damp atmosphere or are subject to condensation of moisture when out of service for long periods. Motors… Read more

Dec 14, 2010 | Electric Motor

AC motor stator windings

Forms of Separation (2) – Fundamentals

In accordance with the Standard, separation of the various elements of an Assembly: busbars, functional units, terminals, can be claimed providing one or more of the following criteria are met:… Read more

Dec 13, 2010 | Low Voltage

Forms Of Separation - Introduction

Shielding Of Power Cables

Medium and high-voltage power cables, in circuits over 2000 volts, usually have a shield layer of copper or aluminum tape or conducting polymer. If an unshielded insulated cable is in… Read more

Dec 12, 2010 | Cables

Shielding of power cables

Hydro vs. Wind vs. Solar Power?

Matthew Stein, author of When Technology Fails: A Manual for Self-Reliance, Sustainability, and Surviving the Long Emergency wrestles with that very question in his book. Here’s an excerpt: No single… Read more

Dec 11, 2010 | Hydropower

Hydro vs. Wind vs. Solar Power?

IEC 62271-200 – HV Switchgear And Controlgear

Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV Switchgears are important nodal points in modern power distribution. Correspondingly… Read more

Dec 09, 2010 | High Voltage

IEC 62271-200