Search

Premium Membership ❱❱

Study specialized electrical engineering articles and technical papers in low/high voltage areas. Save 15% on PRO plan with code EEP21.

Home / Technical Articles / Why Bats Are Insanely Attracted To Wind Turbines?

Bat Kills at Wind Turbines

Recent studies have reported large numbers of bats being killed at wind farms in many parts of North America and Europe. Project monitoring has also discovered significant bat mortality at the Mexico La Venta II wind farm.

Why Bats Are Insanely Attracted To Wind Turbines?
Why Bats Are Insanely Attracted To Wind Turbines?

Bat kills at wind turbines were first discovered in Australia. Small numbers of bats were first recorded in the United States at wind power projects in California during bird monitoring.

Some time ago, an estimated 1,400-4,000 bats were recorded as killed during 2008 at the Mountaineer Wind Energy Center in West Virginia . High bat mortality at that site has continued since then.

The frequency and number of bat kills at wind turbines are much greater than for any other type of human-built structure.

Unlike birds, bats strike wind towers as well as telecommunications towers, buildings or power lines, but very infrequently.


Bat Mortality from Collisions and Barotrauma

The bat killed by wind turbine blades
The bat killed by wind turbine blades

Bats that fly too close to wind turbines are killed by either direct impact or from major air pressure changes around the spinning rotors.

While bats clearly are killed by direct collision with turbine blades, up to 50 percent of the dead bats around wind turbines are found with no visible sign of injury.

The cause for this non-collision mortality is believed to be a type of decompression known as barotrauma, resulting from rapid air pressure reduction near moving turbine blades.

Barotrauma kills bats near wind turbines by causing severe tissue damage to their lungs, which are large and pliable, thereby overly expanding when exposed to a sudden drop in pressure.

By contrast, barotrauma does not affect birds because they have compact, rigid lungs that do not excessively expand.


Bat Atraction to Wind Turbines

Many species of bats appear to be significantly attracted to wind turbines for reasons that are still poorly understood.

Here we’re gonna try to summarizes the more plausible scientific hypotheses that have been advanced to date. By contrast, birds are not normally attracted to wind turbines, and simply collide with them by accident.

The Eastern Red Bat Lasiurus borealisis typical of the migratory, tree-roosting bat
The Eastern Red Bat Lasiurus borealisis typical of the migratory, tree-roosting bat species that are frequent casualties at some wind farms in North America.

9 Hypotheses for Bat Attraction to Wind Turbines

Various scientific hypotheses have been proposed as to why bats are seemingly attracted to and/or fail to detect wind turbines

The more plausible hypotheses include the following:

1. Auditory Attraction

Bats may be attracted to the audible “swishing” sound produced by wind turbines. Museum collectors seeking bat specimens have used long poles that were swung back and forth to attract bats and then knock them to the ground for collection.

It is not known if these bats were attracted to the audible “swishing” sound, the movement of the pole, or both factors.

2. Electromagnetic Field Disorientation

Wind turbines produce complex electromagnetic fields, which may cause bats in the general vicinity to become disoriented and continue flying close to the turbines.

3. Insect Attraction

As flying insects may be attracted to wind turbines, perhaps due to their prominence in the landscape, white color, lighting sources, or heat emitted from the nacelles, bats would be attracted to concentrations of prey.

4. Heat Attraction

Bats may be attracted to the heat produced by the nacelles of wind turbines because they are seeking warm roosting sites.


5. Roost Attraction

Wind turbines may attract bats because they are perceived as potential roosting sites.

6. Lek Mating

Migratory tree bats may be attracted to wind turbines because they are the highest structures in the landscape along migratory routes, possibly thereby serving as ren-dezvous points for mating.

7. Linear Corridor

Wind farms constructed along forested ridge-tops create clearings with linear landscapes that may be attractive to bats.

8. Forest Edge Effect

The clearings around wind turbines and access roads located within forested areas create forest edges. At forest edges, insect activity might well be higher, along with the ability of bats to capture the insects in flight.

Resident bats as well as migrants making stopovers may be similarly attracted to these areas to feed, thus increasing their expo-sure to turbines and thus mortality from collision or barotrauma.

9. Thermal Inversion

Thermal inversions create dense fog in cool valleys, thus concentrating both bats and their insect prey on ridge-tops.


Bat Species Most Significantly Affected

The bat killed by wind turbine blades
The bat killed by wind turbine blades

In North America, migratory bat species have been found dead at wind farms much more frequently than the resident (non-migratory) species, even in areas where the resident species are more common throughout the summer.

Eleven of the 45 species of bats that occur in North America north of Mexico have been found dead at wind farms, but most studies report that the mortality is heavily skewed towards migratory, tree-roosting species such as Hoary Bat Lasiurus cinereus, Eastern Red Bat Lasiurus borea-lis, and Silver-haired Bat Lasionycteris noctivagans.

While these three species are not listed as threatened or endangered under the U.S. Endangered Species Act, they are classified as of Special Management Concern at the provincial level in Canada. Although the globally endangered Indiana Bat Myotis sodalishas not yet been found dead at wind farms, potential new wind farms within this species’ remaining strongholds could possibly threaten it.

In Europe, 19 of the 38 species of bats found within the European Union have been reported killed by wind turbines.

Although migratory species are among the most numerous casualties, resident bats are also killed in substantial numbers, particularly in forested areas.

Turbine-related bat mortality has been found in every European country in which bat monitoring has been done, except for Poland where no dead bats were found during monitoring at two sites. The highest numbers of bat fatalities have been found in Germany and France, which is almost certainly due to the more extensive monitoring carried out in those countries.


Bats and Windfarms 7 January 2013 (VIDEO)

Cant see this video? Click here to watch it on Youtube.


Bat Detection Technology Demonstration for Wind Turbines (VIDEO)

Bats are worth billions to the agriculture industry due to their natural control of pests. Unfortunately, wind power poses a risk to bats due to the potential for them to be struck by spinning turbine blades.

EPRI is working with We Energies to demonstrate a specialized technology that uses ultrasonic microphones to detect the presence of bats. If the microphones pick up the high-pitched squeaks and clicks bats make, the turbines will automatically shut down and restart when the bats are out of range.

The project is focused on reducing bat mortality at wind farms while avoiding long-term curtailments and maximizing electricity production.

Cant see this video? Click here to watch it on Youtube.

In Latin America, 19 bat species were represented among the 123 individual bats found dead under wind turbines in 2007-2008 at the La Venta II project in southern Mexico. In 2009, 20 different bat species were involved (INECOL 2009).

Thirteen of these species are insectivores, while two feed mainly on nectar, and two on fruit.

The most commonly killed species, Davy’s Naked-backed Bat Pteronotus davyi, is thought to be resident in the area, although some other frequently killed species at La Venta II are considered to be migratory.

Interestingly, despite the enormous concentrations of mi-gratory birds that pass over or through the La Venta II wind farm (over 1 million per year), monitoring data from INECOL show that a larger number of bats are being killed there than birds.

Resource:  Greening the Wind – ENVIRONMENTAL AND SOCIAL CONSIDERATIONS FOR WIND POWER DEVELOPMENT (George C. Ledec, Kennan W. Rapp and Roberto G. Aiello)

Premium Membership

Get access to premium HV/MV/LV technical articles, electrical engineering guides, research studies and much more! It helps you to shape up your technical skills in your everyday life as an electrical engineer.
More Information
author-pic

Edvard Csanyi

Electrical engineer, programmer and founder of EEP. Highly specialized for design of LV/MV switchgears and LV high power busbar trunking (<6300A) in power substations, commercial buildings and industry facilities. Professional in AutoCAD programming.

6 Comments


  1. kamyar elyasi
    Feb 04, 2014

    like


  2. James Barnett
    Feb 04, 2014

    I think this should help. when I was a kid I used to play in the woods, I was at an old wooden bridge and heard some strange noise and looked up and there was a bat flying around. I took a baseball bat that was cut in half and laying on the ground and flung it up in the air. The bat immediately flew to it and the baseball bat hit him and killed him right there, I was amazed. I always thought it was one of them one in a million things but now that I read this I have been able to eliminate some of the 10 theory’s. Hope this helped.

Leave a Reply to kamyar elyasi

Tell us what you're thinking... we care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

six  +  4  =  

Learn to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and electrical guides.