Search

Premium Membership ♕

Save 20% with a coupon BLACKFRIDAY on the PRO Membership Plan and all courses at EEP Academy! Learn from experienced engineers!

Lighting concepts

The definition of individual visual tasks for the purpose of lighting design in a room, as provided for in the EN 12464 standard, opens up new perspectives for lighting design. The quantity and quality of light can now be specified exactly for any task area.

The Lighting Handbook by Zumtobel Lighting GmbH
The Lighting Handbook by Zumtobel Lighting GmbH

Task area related lighting concepts are a customised tool to fully exploit the additional options provided. At the same time they offer financial scope that can be used to improve lighting comfort and enhance the effect of a room.

Visual function

Task area related lighting provides the right amount of light at the best possible quality for every visual task. Uniformity, control of glare and reflections, good contrast rendition and shadow detail are consistently matched to the respective task.

The lighting is adjusted perfectly to the room user’s needs.

Focusing the lighting onto clearly defined areas means saving investment and operating costs.

The funds saved can be used to improve comfort and enhance the room atmosphere, for instance by exciting lighting accents, illuminated walls or dynamic lighting scenarios.

Room related lighting concept
Room related lighting concepts take neither individual task areas nor different visual tasks into account. They are based on the most demanding task performed in the room. The position of the workstation is not defined, the entire room disposes of a uniform lighting quality

Lighting focussed onto individual visual task areas
Lighting focussed onto individual visual task areas provides for varied light design in the room. By illuminating walls, for instance, rooms can be designed to be much more open and attractive; dynamic lighting situations can enhance their visual quality

Optimum energy efficiency

Large buildings provide huge potential for optimisation of energy consumption. Lighting that is consistently focussed onto individual task areas reduces mean illuminance levels and therefore the average expenditure on energy.

Savings can be further increased by using daylight-based lighting management and presence detectors.

Title:The Lighting Handbook – Zumtobel Lighting GmbH
Format:PDF
Size:11.5 MB
Pages:308
Download:Right here | Video Courses | Membership | Download Updates
The Lighting Handbook (by Zumtobel)
The Lighting Handbook (by Zumtobel)

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

3 Comments


  1. Madhavan.D
    Aug 08, 2017

    please give me the idea , I am having 20 years of experience in FMCG and Steel industry and I want start Electrical service business. Kindly suggest and how start the business


  2. sabry
    May 06, 2017

    very used full for me thanks


  3. mohamed maher
    Jan 25, 2016

    Amazing book ,,
    M.Maher

Leave a Reply to sabry

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

22  +    =  32

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Save 20% with coupon BLACKFRIDAY.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.