Search

Premium Membership ♕

Save 20% with a coupon BLACKFRIDAY on the PRO Membership Plan and all courses at EEP Academy! Learn from experienced engineers!

Home / Download Center / Electrical Engineering Books and Technical Guides / Electricity generation, t&d guides / Power loss reduction in large urban ring main networks (optimisation, capacitor addition)

Interconnected ring main network

Due to low voltage on the distribution side of the power system, high currents and power losses are experienced. The pressure on utilities to improve the overall efficiency in the power system has forced them to concentrate on reducing the power loss on the distribution level, since it contributes most power losses in the power system.

Power loss reduction in large urban ring main networks
Power loss reduction in large urban ring main networks (optimisation and capacitor addition) – photo credit: Anord Mardix

Researchers have discussed and developed different algorithms to solve the power loss reduction problem in distribution networks. However, these methods were developed for radial network operations. However, most large urban distribution networks are operated as ring networks.

Furthermore, although ring main networks are believed to have less power losses compared to radial networks, loss of an important component in a ring main network can cause an increase in power losses leading to power shortage in the network. To improve the state of a network is the task of optimal load flow studies.

There is thus a need for network engineers to identify efficient ways to deliver power to loads efficiently in ring networks. This is a great shortcoming in the literature.

This thesis focuses on developing an efficiency plan that can be used by network operators in response to a failure of a major component such as a substation infeed or a primary U/G cable. The developed efficiency plan is using the capacitor addition and network reconfiguration techniques to give the optimal configuration for power loss reduction.


Development of the efficiency plan work flow diagram

Figure 1 shows the one-line diagram of the large urban interconnected ring main distribution network that was used to evaluate and develop the efficiency plan (methodology).

Such a network is typical in industry and consists of multiple ring main networks.

Large urban interconnected ring main networks RM1 and RM2
Figure 1 – Large urban interconnected ring main networks RM1 and RM2

The network shows two interconnected ring main networks namely Ring main Network 1 (RM1) and Ring main Network 2 (RM2). Both ring main networks, RM1 and RM2, have a voltage source of 66∠0° kV and a frequency of 50 Hz. The two networks are interconnected via U/G Cables 13, 14 and 15.

RM1 has a step down transformer rated at 7 MVA, 66/11 kV with two primary U/G Cables, 1A and 2A. U/G Cables, 3A, 4A, 5A, 6A, 7A and 8A complete the ring main system of RM1.

RM2 has a source step down transformer rated at 10 MVA, 66/11kV with three primary U/G Cables 1B, 2B and 3B and secondary U/G Cables 4B, 5B, 6B, 7B, 8B, 9B, 10B, 11B and 12B. The load ratings, transformer ratings and U/G cable ratings for both networks are shown in Tables A.1, A.2 and A.3, in Appendix A.

The studies will mainly be focused on the RM1 network. The RM2 network will however be considered in the case of network configuration when extra power is needed at RM1.

Efficiency plan: work flow diagram
Figure 2 – Efficiency plan: work flow diagram

Efficiency plan Methodology

Figure 2 shows an efficiency plan work-flow diagram. The work-flow diagram depicts an empirical approach for finding the optimal configuration that will minimise the power losses in a ring main network that is under a contingency condition, while satisfying the given constraints.

The flow diagram was evaluated using the ring main network in Figure 1. The load flow procedures find a series of configurations with different status of switches and addition of capacitors such that the power losses are successively reduced.

The network was analyzed using DIgSILENT powerfactory and Power Systems Computer Aided Design (PSCAD) software to obtain steady-state and time domain results, respectively. The parameter models for DIgSILENT and PSCAD are shown in Appendices A and B respectively.

The load flow procedures of the proposed method are mainly composed of power loss and efficiency calculations, busbar voltages and cable/feeder loading determination and empirical approach application.

Title:Power loss reduction in large urban ring main networks (optimisation, capacitor addition) – Julia Dhimbulukweni Iindombo – Thesis submitted in fulfilment of the requirements for the degree Master of Technology: Electrical Engineering in the Faculty of Engineering at the Cape Peninsula University of Technology
Format:PDF
Size:1.9 MB
Pages:118
Download:Right here | Video Courses | Membership | Download Updates
Power loss reduction in large urban ring main networks (optimisation, capacitor addition)
Power loss reduction in large urban ring main networks (optimisation, capacitor addition)

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

4 Comments


  1. ISAIAH NJAMBA
    Aug 26, 2020

    What is the difference between circuit breaker and circuit main Earth


  2. Mohamed Omar Morad
    Apr 14, 2020

    This article was very helpfull for my information


  3. prakash Thanekar
    Apr 14, 2020

    we study of our plant Harmonic Audit find out 15 to 20 % current AThd &4 to 5 % voltage distoration he suggested installed 1200 Kvar active harmonic filter
    but we are confuse how much return revenue come out our organation


  4. Theuns
    Apr 13, 2020

    Good thesis for a change! Well done

Leave a Reply to prakash Thanekar

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

76  −    =  68

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Save 20% with coupon BLACKFRIDAY.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.