Home / Download Center / Electrical Engineering Books and Technical Guides / Relay control and protection guides / Protection of parallel (double) circuit transmission lines in modern power systems

Distance protection performance problems

This paper describes different cases of parallel transmission lines and analyzes some well known application problems associated with their protection. Distance protection performance problems are in the focus due to the fact that they are the most commonly used protection type for parallel transmission lines.

Protection of parallel circuit transmission lines in modern power systems
Protection of parallel circuit transmission lines in modern power systems (photo credit: SIEMENS)

The behavior of ground overcurrent protection on double circuit applications is also discussed in the paper.

Finally, some advanced features of communications assisted schemes, non-communications protection schemes and fault location for double circuit lines are discussed.


Application considerations

Mutual coupling and the possibility of the occurrence of cross country faults are possibly the main sources of problems and complexity when faults in multi-circuit lines are to be studied.

Different double line topologies have to be considered for various fault conditions and the recommended solutions that are available for these scenarios are often not implemented in practice.

The use of single line settings are often only considered without analyzing the mutual coupling effects. Also, cross-country faults may be deemed a low risk, but in the event of such a fault may cause incorrect tripping operation which could lead to stability problems on already weak-end networks.


Mutual Coupling Effects

Double circuit lines on the same towers (Figure 1) or on the same right-of-way are very common.

Double circuit line
Double circuit line

They can have many different configurations based on the system topology and how they are connected at the two ends of the double circuit line.

For example:

  1. They are not connected to the same bus at either end of the line.
  2. They are connected to the same bus at only one end of the line.
  3. They are connected to the same bus at each end of the line.

Figure 2 shows the last case that will be the focus of the analysis in the paper.

Example parallel line system
Figure 2 – Example parallel line system

The parallel line configuration is further complicated when the two (or more) lines on the same tower or right-of-way are at different voltages.

The main difference between a single transmission line and a transmission line on the same tower or parallel along the same right-of-way with one or more other lines is the mutual coupling.

Title:Protection of parallel (double) circuit transmission lines in modern power systems – A. Apostolov (OMICRON electronics), D. Tholomier, S. Sambasivan and S. Richards (all from AREVA T&D Automation)
Format:PDF
Size:392.8 KB
Pages:17
Download:Right here | Video Courses | Membership | Download Updates
Protection of parallel (double) circuit transmission lines in modern power systems
Protection of parallel (double) circuit transmission lines in modern power systems

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

2 Comments


  1. Azubuike nwaobi
    Jul 23, 2020

    I love this work very much an I will love to learn more about electricity


  2. Kothamasu Venkata Rao
    Jun 13, 2019

    All your documents will be very useful for all the field engineers working in Power Plants, Switch Yards & Transmission Lines Maintenance. I am studying them and enjoying the priceless worth of knowledge through your documents.
    You are doing a lot of service to all Electrical Engineers by distributing so many documents on several topics on Electrical Systems & Electrical Protections etc…

Leave a Reply to Azubuike nwaobi

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

  ⁄  5  =  1

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Save 20% with coupon BLACKFRIDAY.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.