Search

Premium Membership ♕

Save 20% with a coupon BLACKFRIDAY on the PRO Membership Plan and all courses at EEP Academy! Learn from experienced engineers!

Home / Technical Articles / What Is The Purpose Of Wind Farm Lighting?
What Is The Purpose Of Wind Farm Lighting?
What Is The Purpose Of Wind Farm Lighting?

Aircraft Warning Lights

Wind farm lighting includes:

  1. Aircraft warning lights that are installed on tops of some turbine nacelles and
  2. Night lights around wind farm buildings, parking lots, or other facilities.

Aircraft warning lights on top of tall telecommunications towers are known to be highly problematic for night-flying migratory birds (though not bats) during cloudy weather when the birds cannot navigate via the stars and are aÄ´racted to the lights, thereby colliding with the towers, guy wires, or each other.

Recent U.S. research indicates that white strobe lights with brief pulses are more bird friendly than solid or slowly pulsating red or white lights, since they seem to be less of an attractant to migrating birds on cloudy nights.

The windy sites most favorable for wind farm development often, though not always, have clear skies at night when night-flying birds are not attracted to artificial lights.

To minimize the risks that night-flying migrant birds will be attracted to wind turbines during overcast weather, aircraft warning lights would ideally be:

  1. White strobe lights and
  2. Placed a top a limited number of turbines to help show the wind farm outline, rather than on every one, consistent with national and local regulatory requirements.

In many low-risk cases far away from airports, such lights might not be needed at all; for example, U.S. law requires aircraft warning lights only on structures 200 feet or higher.

If aviation regulations provide flexibility regarding the type of aircraft warning lights to be used, it would also be important to consult with local residents regarding their aesthetic preferences, while also explaining the bird-friendly advantages of white strobe lights.

At the Mexico La Venta II project, only a small number of the 98 turbines have aircraft warning lights, which appears to be adequate for showing any pilots that might be in the area that there are multiple structures around, without potentially at-tracting numerous migrating birds to the turbines on overcast nights.

Night lighting close to ground level can also be managed to minimize bird and bat mortality.

Night lights around worker compounds, parking lots, and other wind farm facilities can attract to the wind farm migratory birds during cloudy weather, as well as bats and nocturnal birds (owls and nighjars) that seek out the flying insects that con-centrate around night lights.

In this regard, wind farm night lighting can be managed to minimize risks to birds and bats in ways that do not compromise worker safety and operational security.

These approaches include the use of:

  1. Sensors and switches to keep lights off when not needed and
  2. Lighting fixtures that are hooded and directed downward to minimize the skyward and horizontal illumination that could attract night-flying birds and bats to the vicinity of wind turbines.
Wind turbine lighting signalization
Wind turbine lighting signalization (on photo: SIEMENS wind turbine)

Resource: Greening the Wind | Environmental and Social Considerations for Wind Power Development – George C. Ledec, Kennan W. Rapp and Roberto G. Aiello

Premium Membership

Get access to premium HV/MV/LV technical articles, electrical engineering guides, research studies and much more! It helps you to shape up your technical skills in your everyday life as an electrical engineer.
More Information
Edvard Csanyi - Author at EEP-Electrical Engineering Portal

Edvard Csanyi

Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.

I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.

Profile: Edvard Csanyi

3 Comments


  1. Mike Pasqualetti
    Apr 08, 2017

    Do you know where you got the photo of the wind turbines at night? I would like to use it in a academic presentation if I may. Thank you.


  2. kanchi
    Apr 21, 2014

    Super


  3. Luciano Vasconcelos Crispiniano
    Feb 05, 2014

    Boa noite Srs, gostaria de receber informações sobre Wind power applications!

    Att Luciano

Leave a Reply to Luciano Vasconcelos Crispiniano

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

12  −    =  8

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Save 20% with coupon BLACKFRIDAY.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.