Search

Premium Membership ♕

Save 20% with a coupon BLACKFRIDAY on the PRO Membership Plan and all courses at EEP Academy! Learn from experienced engineers!

Electrical Plan Review
Electrical Plan Review – Overcurrent Protection and Devices, Short-Circuit Calculations, Component Protection, Selective Coordination, and Other Considerations – COOPER Bussmann

Objectives of Electrical Plan Review //

Content of Electrical Plan Review Booklet:

  1. Overcurrent Protection and Devices,
  2. Short-Circuit Calculations,
  3. Component Protection,
  4. Selective Coordination and
  5. Other Considerations

By reviewing this brochure, the Electrical Inspector, Electrical Contractor, Plan Examiner, Consulting Engineer and others will be able to:

Understand and discuss //

  • The critical National Electrical Code® requirements regarding overcurrent protection.
  • Short-circuit currents and the importance of overcurrent protection.
  • Three ratings (voltage, ampere, and interrupting) of overcurrent protective devices.
  • That the major sources of short-circuit currents are motors and generators.
  • That transformers are NOT a source of short-circuit current.
  • Calculation of short-circuit currents using the simple POINT-TO-POINT method and related charts.
  • Current-limitation and use of let-through charts to determine the let-through current values (peak & RMS) when current-limiting overcurrent devices are used to protect electrical components.
  • Series rated combinations and proper application of series rated combinations.
  • Selective coordination of overcurrent protective devices.
  • The meaning and importance of electrical terms commonly used relating to overcurrent protection.
  • Maintenance, testing, resetting, and replacement requirements of overcurrent protective devices.

Realize and check //

  • Realize that whenever overcurrent protection is discussed, the two most important issues are:
    • How much current will flow?
    • How long will the current flow?
  • Electrical plans to determine conformance to the National Electrical Code® including:
    • Short-circuit currents,
    • Interrupting ratings,
    • Short-circuit current (withstand) ratings,
    • Selective coordination,
    • Ground faults, grounding electrode conductors,
    • Equipment grounding conductors, etc.
Title:Electrical Plan Review – Overcurrent Protection and Devices, Short-Circuit Calculations, Component Protection, Selective Coordination, and Other Considerations – COOPER Bussmann New
Format:PDF
Size:1.62 MB
Pages:45
Download:Right here | Video Courses | Membership | Download Updates
Electrical Plan Review – Overcurrent Protection and Devices, Short-Circuit Calculations, Component Protection, Selective Coordination, and Other Considerations – COOPER Bussmann
Electrical Plan Review – Overcurrent Protection and Devices, Short-Circuit Calculations, Component Protection, Selective Coordination, and Other Considerations – COOPER Bussmann

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

5 Comments


  1. DEMELASH DESALEGN
    Apr 24, 2019

    I cant download the electrical plan review.Can I get 15kv underground overhead cable installation document?


  2. UMAR TANIMU UMAR
    Feb 15, 2019

    Good morning, as a student of elect/elect engineering i always learn one or two things from your article . i am thing on the project i will embark on during my final year so if there any kind of project that i will do that will be use solve human problem in today’s activity.


  3. imad
    Mar 15, 2016

    I cant download the electrical plan review


  4. grana
    Oct 15, 2015

    Hi.., admin the file can’t for download, please share another linked url or you can send that file to my email.

    Very appreciate for your help. Thank you..


  5. Robert Odhiambo
    May 17, 2015

    Great book indeed…

Leave a Reply to Robert Odhiambo

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

18  +    =  19

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Save 20% with coupon BLACKFRIDAY.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.