Description
Learn the essentials of transformer connections – vector groups. The course starts with the vector and phasor basics and their difference. What phase shift and phase angle are and how phase shift is created in a transformer are covered in detail in the following lessons.
The course consists of 15 lessons and 1h 26 min. total duration.
You will learn why transformers are connected to form specific vector groups, the delta and star connections, and the relationship between line and phase voltages and current. What are the advantages and disadvantages of connecting transformer winding in Star or Delta? The answers are covered in great detail.
We will discuss the 26 MVA transformer nameplate.
The course continues with defining vector group dy11, clock method, lead and lag concepts. Finally, you will learn to draw vector group and connections of dy11,dy1, yd1, yy0,dd0, yy6, and yz1 configurations.
The following topics are covered in this masterclass:
- What is vector
- What is phasor
- Difference between vector and phasor
- What is phase shift & phase angle
- How phase shift is created in transformer
- Why transformer with different phase shift exist
- Why at least one delta winding is provided
- Circuit breaker auxiliary contacts
- Why transformers are connected to form certain vector group
- What is delta and star connection and relationship of line and phase voltages and current
- Advantage and disadvantage of connecting transformer winding in star or delta
- Where to place HT windings, LT windings and tap changer windings
- Discuss 26MVA transformer name plate
- How to define vector group i.e. dy11
- What is clock method, lead and lag concept
- Draw vector group and connections of dy11, dy1, yd1, yy0,dd0, yy6 and yz1
Who Is This Course For
- Electrical Engineering Students
- Electrical Engineering Graduates
- Electrical Engineers who work in the field of substations and transformers
- Electrical Control Engineers
- Power/Utility Engineers
- Technicians
Requirements
- Basic knowledge of transformers
- A good will for learning
- A cup of coffee

Low Voltage Distribution and Lighting Design Bundle: AutoCAD, Dialux, Excel (Course + Coursebook)
Low Voltage Power Distribution Course For Beginners
Electrical Designing and Drafting Course (Part 2)
Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections
Power System Analysis, Modelling, Load Flow and Fault Studies for True Engineers
Mastering Power Substations: Electrical Equipment, Busbar Schemes and Relay Protection
Gas-Insulated Switchgear Course: Design, Installation, Operation and Maintenance, Testing
Understanding the Concepts Behind Power System Reliability
A Detailed Course to Wave Energy Conversion For True Engineers: Theory and System Implementation
Learn How to Perform Calculations of Electrical Loads and Design the Protection System
Relay Control and Protection Bundle: Complete Relay Circuitry and Schematics (Five Courses)
Practical Course to Ring Main Unit and Medium Voltage Cables in Ring Power Distribution Systems
The Essentials of Capacitor Banks: Connections, Calculations and Relay Protection
Electrical Designing and Drafting Bundle (Two Courses)
Power Engineering Course: Relay Control and Protection For LV/MV/HV Switchgear
Generation and Measurements of High Voltage and Overhead Transmission Line Insulators
Course to Relay Circuitry and Understanding Control and Protection Schematics
MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar
Complete Power Engineering Bundle (Six Courses)
Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting 



Reviews
There are no reviews yet.