Mastering Power Substations: Electrical Equipment, Busbar Schemes and Relay Protection

This masterclass course provides a deep understanding and knowledge in power substations. You will learn different substation types, their differences, electrical equipment (switchgear, transformers, breakers, isolators, etc.), as well as busbar schematics and relay protection principles. The course consists in 97 topics and 9h 2min total length.

Course Description

This masterclass course provides a deep understanding and knowledge in power substations. You will learn the most common substation equipment such as switchgear, transformers, isolators, earth switch, CTs & VTs, shunt reactor, batteries and others.

The great attention is given to the busbar schemes (configurations), transformer protection and substation relay control & protection.

The course consists in 22 lessons, 97 lessons and 9h 2min total length.

The course starts with discussing three most common substation types (air-insulated, gas-insulated, and hybrid), their comparison in working principle and layout. You will learn the main components installed in most of substations, such as switchgear, transformers, isolators, earth switches, instrument transformers (CTs, VTs), fuses, capacitor banks, shunt reactors and many others.

You will learn about batteries installed in power substation, charger techniques and how to depict batteries in a single-line diagram.

The next big chapter will cover the most common busbar configurations and layouts, such as single-Bus single-breaker scheme (with and without Bus Section CB), double-bus single-breaker scheme, one-and-half breaker scheme, ring or mesh busbar scheme and few others.

In the the next chapter will explain in great detail relay protection in power substation. We will start with a philosophy and characteristics of control and protection systems. You will learn ANSI Codes for protection devices and faults in power system.

You will learn all the types of protection relays, tripping relays, lockout relays, auxiliary relays and tripping coils.

Finally, we’ll discuss a medium voltage switchgear and all its compartments. You will also learn the essentials about substation earthing.

Following topics are covered in this course:

  • What are substations?
  • Types of substations
  • What are air insulated substation?
  • What are gas insulated substations?
  • What are hybrid substation?
  • Comparision of GIS and AIS substations
  • GIS & AIS foot print comparison
  • What is difference between Substation and Grid Station?
  • Why substations are required?
  • What is Ferranti Effect?
  • How was earlier power distribution look like?
  • Development of 1st AC Transmission Line and Substation
  • Brief history of Tesla Lab
  • Components of substation
  • Development of 1st AC Transmission Line and Substation
  • Transformer basics
  • Induced Voltage & per turn relationship.
  • Transformer Turn Ratio and full load current calculations.
  • Percentage Impedance of Transformer
  • Transformer Vector Group
  • Polarity of transformer
  • Radiator in Transformer
  • Types of Cooling, Why Two ratings are given at name plate of transformer
  • Buchholz Relay, installation, operation, construction
  • Sudden Oil Pressure Relay
  • Oil and Winding Temperature Indicator
  • Oil Level Indicator
  • Pressure Relief Device
  • Bushing of Transformer and Bushing Test Tap
  • Rupture Disc
  • Tap Changers Types and requirements
  • On load and Off load tap changers
  • Transformer General Arrangement Drawing
  • Transformer Name Plate.
  • Silica Gel and Breather
  • Isolator
  • Circuit Breaker
  • Earth Switch
  • Voltage Transformer
  • Current Transformer
  • Cable Sealing End
  • SF6 to Air Bushing
  • Busbar in substation
  • Visual inspection of transformer
  • Auxiliary Transformer
  • NGR Neutral Ground Resistor
  • Application of NGR using ETAP
  • Fuses
  • Shunt Reactor
  • Shunt Reactor at Single Line Diagram
  • Current Limiting Reactor
  • Communication System Between Substations PLC and Fiber Optic
  • Capacitor Bank In substation
  • Surge Arrestor
  • Lighting Rod and Mast
  • Thermal Imaging Technique
  • Busbar Scheme, Single bus Single Breaker Scheme
  • Single Bus and Single Breaker Scheme with Bus Section CB
  • Double Bus Single Breaker Scheme
  • One and Half Breaker Scheme
  • Ring or Mesh Busbar Scheme
  • Double Bus Double Breaker Scheme
  • Main and Transfer Bus System
  • Double Bus System with bypass isolator
  • Concept of Interlocking at Substation
  • Philosophy of Protection System
  • Control and Protection System in Substation
  • ANSI Codes for presentation of devices
  • Faults in Power System
  • Characteristics of Protection System.
  • Protection Zone Over lapping and Blind Zones in Power System
  • Protection Relays and its type
  • Induction Disk Type Electromechanical Relay
  • Attracted Armature Type Relay
  • Static, Digital and Numerical Relays
  • Protection Relays types with respect to function
  • Tripping Relays, Lockout Relays, Aux Relays and tripping coils
  • 85 Batteries in Substation, Single line diagram, charging techniques
  • MV Switchgear, compartments, MV compartment, CB compartment, Busbar Compartment, LV compartment
  • Substation Earthing system

Course Summary

  1. Introduction
  2. Substation History
  3. Substation Types and Comparison
  4. Substation Components
  5. Transformer
  6. Circuit Breaker
  7. Fuses
  8. Isolator – Disconnector
  9. Earth Switch
  10. Current and Voltage Transformers
  11. Capacitor, Surge Arrester and Lightning Protection
  12. Shunt Reactor and Current Limiting Reactor
  13. Neutral Ground Resistor (NGR)
  14. Cable Sealing End
  15. SF6 to Air Bushing
  16. Busbar Schemes and Arrangements
  17. The Concept of Interlocking in Substation
  18. Substation Communications
  19. Substation Batteries
  20. Substation Relay Protection
  21. Medium Voltage Switchgear
  22. Substation Earthing

Who Is This Course For

  • Anyone who wants to learn power substations from scratch
  • Electrical Engineering Students
  • Electrical Engineering Graduates
  • Electrical Engineers who work in the field of substations and switchgears
  • Electrical Control Engineers
  • Electricians
  • Power/Utility Engineer

Requirements

  • Passion to learn
  • The basic electrical principles

Downloadable course materials

After purchasing the course, students can download the following materials:

  1. 11kV Capacitor Bank Drawing.pdf
  2. 132.11kV ETAP Transformer Groud Fault NGR .pdf
  3. 132.11kV ETAP Transformer Groud Fault Solidly Ground .pdf
  4. 132kV Line Protection Panel Relay and Metering Single Line Diagram.pdf
  5. 132kV Single Line Diagram.png
  6. 132kV Substation Earthing Layout.pdf
  7. 220V SLD reference .pdf
  8. 26MVA AVR Panel Schematics.pdf
  9. 26MVA OutDoor Panel Schematics.pdf
  10. 26MVA Trafo Data Sheet.pdf
  11. 26MVA Trans auxiliary_panel.pdf
  12. 26MVA Transformer cooling_calc.pdf
  13. 26MVA Transformer Section Drawig .pdf
  14. 500kV Shut Reactor Name Plate.jpg
  15. AC SLD .pdf
  16. ANSI Code List.pdf
  17. Aux Transformer Data Sheet.pdf
  18. Aux Transformer Name Plate.png
  19. DC SLD.pdf
  20. Distribution Transformer Nameplate.png
  21. General Arrangment-26MVA.pdf
  22. Line Isolator Name Plate.jpg
  23. NGR Name Plate.pdf
  24. NGR Name Plate.png
  25. NGR SLD.png
  26. Neutral Ground Reactor pic.jpg
  27. Rating plate 20_26.pdf
  28. Substation Presentation.pdf
  29. Switch Yard Pic .jpg
  30. Technical date sheet-Surge Arrestor.docx
  31. Telecom DC SLD.pdf
  32. Transformer Vector Group Connection Diagrams.png

Course Content

Lesson Content
0% Complete 0/1 Steps
Lesson Content
0% Complete 0/1 Steps
Lesson Content
0% Complete 0/1 Steps
Lesson Content
0% Complete 0/1 Steps
Lesson Content
0% Complete 0/1 Steps

About Instructor

Muhammad

Muhammad Kashif Shamshad is an Electrical Engineer and has more than 17 years of experience in operation & maintenance, erection, testing project management, consultancy, supervision, and commissioning of Power Plant, GIS, and AIS high voltage substations ranging up to 500 kV HVAC & ±660kV HVDC  more than 10 years experience is with Siemens Saudi Arabia. He completed over 20 high voltage substation projects, Operation & Maintenace of Substation & Power plants in Pakistan and Saudi Arabia for different electric utilities including Saudi Electricity Company (SEC), Saudi Aramco, SABIC, Marafiq, National Transmission & Despatch Company (NTDC), WAPDA, and K-Electric. Also, he led testing and commissioning teams to implement electrical infrastructure projects for many types of industrial clients (Steel, Petrochemical, etc.) in both countries, Pakistan and Saudi Arabia.

20 Courses

+209 enrolled
Not Enrolled

Course Includes

  • 22 Lessons
  • 97 Topics
  • Course Certificate
  • Lifetime Access