Sale!

Relay Control and Protection Bundle: Complete Relay Circuitry and Schematics (Five Courses)

125.00 $

Learn the essentials of relay protection and control in power systems. This includes a complete relay circuitry and a deep understanding of all control and protection aspects. Special attention is paid to reading and analyzing schematics of transformer differential and distance protection. This bundle includes five courses in a total duration of 33 hours 47 mins.

Description

Learn the essentials of relay protection and control in power systems. This includes a complete relay circuitry and a deep understanding of all control and protection aspects. Special attention is paid to reading and analyzing schematics of transformer differential and distance protection. This bundle includes five courses in a total duration of 33 hours 47 mins.

This bundle includes the following courses. Click on each course to see the details:

4 Lessons

Course to Relay Circuitry and Understanding Control and Protection Schematics

This course covering basic level to intermediate will teach you to understand relay circuitry and read and analyze control and protection schematics.

24 Lessons

The Essentials of Relay Protection and Control in Power Systems

Learn power system protection and control concepts, protection schemes and relays, primary & secondary equipment, and electrical wiring with practical examples. 85 lectures in 9h 11m total course length.

40 Lessons

Learn to Read and Analyze Circuit Breaker Schematics and Control Wiring Diagrams

This is an intermediate to advance level course dedicated to schematics and control wiring diagrams of high-voltage and medium-voltage circuit breakers (applicable to power substations, switchyards, power plants, etc.). 39 lessons in 7h 14min total course length.

22 Lessons

Transformer Differential Protection Course: Understanding Schematics, Relay Settings and Testing

Learn how to analyse and troubleshoot transformer differential protection schematics, relay setting calculations and trip characteristics. Study transformer winding connections from vector diagram and drawing relay settings calculations curve. 22 lessons in 3h 53m total course length.

46 Lessons

Distance Protection Course: Learn How Distance Relay Protects Line and How to Set It Correctly

The course is dedicated to a deep understanding of distance relay protection and correct setting calculations. The course starts with relay characteristic angle and fault characteristics and continues with detailed explanations of impedance relays, Mho and offset Mho relay, etc. 45 lessons in over 5 hours.

Additional information

Brand

EEP – Electrical Engineering Portal

Manufacturer

EEP Academy

Reviews

There are no reviews yet.

Be the first to review “Relay Control and Protection Bundle: Complete Relay Circuitry and Schematics (Five Courses)”