Motor Control Schematics Course For True Engineers

Welcome to the "Motor Control Schematics Course For True Engineers" - a schematic understanding course that will teach you the fundamentals of drawing / schematics associated with motor control. The course covers devices utilized in schematics (auxiliary relay, contactor, timer, etc.), star-delta starter circuit, Dahlander motor connection, sequential motor switching, speed control of two-winding motor, etc. The course consists of 22 lessons in 2h 32min. total duration.

Course Description

Welcome to the “Motor Control Circuits Course For True Engineers” – a schematic understanding course that teaches the fundamentals of drawing / schematics associated with motor control. Training begins with an explanation of the devices utilized in schematics, such as the auxiliary relay, contactor, and timer.

Later, we’ll cover star-delta starter circuit, Dahlander motor connection, sequential motor switching, and speed control of two-winding motor.

The course consists of 22 lessons in 2h 32min. total duration. So, take a cup of coffe and start learning!

It is ensured that anyone with little to no expertise with schematics can learn and perfect the skill.

Trainer has more than 18 years of field experience, having worked at 11/132/220/500kV substations, a 1263MW power plant, and a 660kV HVDC system. SIEMENS, ABB, GE, SEC, KE, WAPDA, NTDC, ARAMCO, SABIC, and MARAFIQ are some of the firms with whom I have worked.

Trainer has conducted hundreds of online and offline trainings, therefore it will be beneficial to attend this training and gain field experience.

Topics covered in this course are as follows:

  • Understand basics of Schematics
  • Auxiliary Relays
  • NO & NC Contact of Relays
  • Contactors
  • Power & Aux contacts of contactors
  • Differentiate between Contactor & Aux Relays
  • Simulation of Aux & Contactor
  • Early Make, Late Break Contacts
  • Break Before Make & Make Before Break Contacts
  • Timer , On Delay & Off Delay
  • MCB and Its function
  • Status of different components in drawings
  • Understand Seal In / Latching / holding contact
  • Simulate the Seal In contact
  • Direct Online Starter circuit
  • Adding start & stop indication to motor circuit
  • Motor direction control circuit
  • Motor & Power Control terminologies
  • Benefits of using Aux relay, contactors
  • Contact bouncing & its effect on motor & how to avoid it
  • AC Supply change over manual control circuit
  • AC Supply change over automatic control with priority to Grid / Generator
  • Star Delta Starter Circuit
  • Dahlander Motor Connection
  • Sequential Motor switching
  • Speed control of two winding motor

Who Is This Course For

  • Anyone who wants to learn motor control circuits and motor control schematics from scratch
  • Electrical Engineering Students
  • Electrical Engineering Graduates
  • Electrical Control Engineers
  • Electricians

Requirements

  • Passion to learn electrical drawings
  • The basic electrical principles

Downloadable course materials

After purchasing the course, students can download the following materials:

  1. Motor Control presentation (PDF)
  2. Switchgear and Motor Control Centres in Oil, Gas and Petrochemical Industry (PDF)
  3. Basic wiring for motor control – Technical data guide (PDF)
  4. The Basics of Motor Control Centers - MCCs (PDF)
  5. Electric motors – and how to improve their control, protection (PDF)

About Instructor

Muhammad Kashif

Muhammad Kashif Shamshad is an Electrical Engineer and has more than 17 years of experience in operation & maintenance, erection, testing project management, consultancy, supervision, and commissioning of Power Plant, GIS, and AIS high voltage substations ranging up to 500 kV HVAC & ±660kV HVDC  more than 10 years experience is with Siemens Saudi Arabia. He completed over 20 high voltage substation projects, Operation & Maintenace of Substation & Power plants in Pakistan and Saudi Arabia for different electric utilities including Saudi Electricity Company (SEC), Saudi Aramco, SABIC, Marafiq, National Transmission & Despatch Company (NTDC), WAPDA, and K-Electric. Also, he led testing and commissioning teams to implement electrical infrastructure projects for many types of industrial clients (Steel, Petrochemical, etc.) in both countries, Pakistan and Saudi Arabia.

20 Courses

+44 enrolled
Not Enrolled

Course Includes

  • 22 Lessons
  • Course Certificate
  • Lifetime Access