Course Description
This course is dedicated to modelling and analysis using ETAP software and its functionalities for successful design & solving various power system practical problems. ETAP is an analytical engineering software which is helpful for an electrical engineer to simulate and analyze the steady-state and dynamic power system. It is used by various sectors such as Generation, Transmission, Distribution, Industrial, Transportation and Low voltage.
This course will help you to achieve your goals to become a true ETAP and power system expert.
The course will begin with the software overview, basics of one-line diagram creation, data entry, and quickly expands the users’ knowledge to include methods to automatically perform multiple ‘what if’ studies using multiple scenarios.
Topics are explained with hand calculations, and results are compared with ETAP software to make it easier for the attendees to understand the concepts.
The instructor is an experienced senior engineer who worked on various power system analysis projects, substation/switchyard detailed design & engineering up to 400kV. He’s also very passionate about power system analysis & power system protection subjects. He has published various papers in IEEE/CIGRE forums.
Course Content
- Load Flow Analysis With Supporting Hand Calculations
- Cable Ampacity and Sizing
- Transformer MVA Sizing
- Short Circuit Analysis With Supporting Hand Calculations
- Protection & Coordination Analysis
- Arc Flash Analysis Using IEEE:1584-2002 Standard
- Motor Starting Analysis
- Transient Stability Analysis
- Harmonic Analysis
- Ground Grid Analysis
Who Is This Course For
- Beginners Who Are New To ETAP Software
- Students Preparing Their Projects/Thesis
- Graduate Electrical Engineers For Cracking The Interviews
- Professionals Working For Companies & Needs To Execute
- Project Engineers
- Electrical Technicians
- Project Managers and Operators
Requirements
- Fundamentals of Electrical Engineering
- Passion To Learn Power System Analysis
- No Any Special Skills and Knowledge Requirement
Downloadable course materials
After purchasing the course, students can download the following documents:
- LF Hand Calculations (xls)
- SC Hand Calculations (xls)
- Why To Use Power System Analysis Software (pdf)
- Creating a New Project (pdf)
- ETAP Software Overview (pdf)
- How To Create Single Line Diagram in ETAP (pdf)
- LF Hand Calculations (pdf)
- Load Flow Example (pdf)
- Cable Ampacity & Sizing (pdf)
- Transformer MVA Sizing (pdf)
- Transformer X by R Calculations (pdf)
- Load Flow Analysis (pdf)
- Short Circuit Analysis (pdf)
- SC Hand Calculations (pdf)
- Short Circuit Analysis Example (pdf)
- Protection & Coordination Analysis (pdf)
- Protection & Coordination Analysis Example (pdf)
- Arc Flash Analysis_2002 (pdf)
- Arc Flash Analysis Example (pdf)
- Motor Starting Analysis (pdf)
- Motor Starting Analysis Example-1 (pdf)
- Transient Stability Analysis (pdf)
- Harmonic Analysis (pdf)
- Ground Grid Analysis (pdf)
Course Content
About Instructor